MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2011.02.012

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2011

The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism.

Aslanides Ioannis M, Toliou Georgia, Padroni Sara, Arba Mosquera Samuel, Kolli Sai

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the refractive and visual outcomes using the Schwind Amaris excimer laser in patients with high astigmatism (>1D) with and without the static cyclotorsion compensation (SCC) algorithm available with this new laser platform.

METHODS

70 consecutive eyes with ≥1D astigmatism were randomized to treatment with compensation of static cyclotorsion (SCC group- 35 eyes) or not (control group- 35 eyes). A previously validated optimized aspheric ablation algorithm profile was used in every case. All patients underwent LASIK with a microkeratome cut flap.

RESULTS

The SCC and control group did not differ preoperatively, in terms of refractive error, magnitude of astigmatism or in terms of cardinal or oblique astigmatism. Following treatment, average deviation from target was SEq +0.16D, SD±0.52 D, range -0.98 D to +1.71 D in the SCC group compared to +0.46 D, SD±0.61 D, range -0.25 D to +2.35 D in the control group, which was statistically significant (p<0.05). Following treatment, average astigmatism was 0.24 D (SD±0.28 D, range -1.01 D to 0.00 D) in the SCC group compared to 0.46 D (SD±0.42 D, range -1.80 D to 0.00 D) in the control group, which was highly statistically significant (p<0.005). There was no statistical difference in the postoperative uncorrected vision when the aspheric algorithm was used although there was a trend to increased number of lines gained in the SCC group.

CONCLUSIONS

This study shows that static cyclotorsion is accurately compensated for by the Schwind Amaris laser platform. The compensation of static cyclotorsion in patients with moderate astigmatism produces a significant improvement in refractive and astigmatic outcomes than when not compensated.

Для цитирования: Aslanides Ioannis M, Toliou Georgia, Padroni Sara, Arba Mosquera Samuel, Kolli Sai. The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2011. DOI: 10.1016/j.clae.2011.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.