MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12028-024-02194-w

Медицинская библиотека · Neurocritical care · 2025

Real-Time Automated Measurements of Optic Nerve Sheath Diameter for Noninvasive Assessment of Intracranial Pressure in Aneurysmal Subarachnoid Hemorrhage.

Netteland Dag Ferner, Aarhus Mads, Sandset Else Charlotte, Sorteberg Angelika, Padayachy Llewellyn, Helseth Eirik, Brekken Reidar

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Optic nerve sheath diameter (ONSD) is a promising noninvasive parameter for intracranial pressure (ICP) assessment. However, in the setting of aneurysmal subarachnoid hemorrhage (aSAH), several previous studies have reported no association between ultrasonically measured ONSD and ICP. In this study, we evaluate ONSD in patients with aSAH using a novel method of automated real-time ultrasonographic measurements and explore whether factors such as having undergone surgery affects its association to ICP.

METHODS

We prospectively included adult patients with aSAH undergoing invasive ICP monitoring. ONSD was obtained using a prototype ultrasound machine with software for real-time automated measurements at the bedside. Correlation between ONSD and ICP was explored, and the ability of ONSD to discriminate dichotomized ICP was evaluated. Abovementioned analyses were performed for the whole cohort and repeated for subgroups by whether the basal cisterns had been surgically entered before ultrasound examination.

RESULTS

Twenty-six ultrasound examinations were performed in 20 patients. There was a positive correlation between ONSD and ICP (R = 0.43; p = 0.03). In the subgroup where the basal cisterns had not been surgically entered before ultrasound examination, there was a stronger correlation (R = 0.55; p = 0.01), whereas no correlation was seen in the subgroup where the basal cisterns had been surgically entered (R = - 0.16; p = 0.70). ONSD displayed an ability to discriminate ICP dichotomized at ≥ 15 mm Hg (area under the curve [AUC] = 0.84, 95% confidence interval [CI] 0.65-0.96). Subgroup analysis revealed a perfect discriminatory ability (AUC = 1, 95% CI 0.81-1) where the basal cisterns had not been surgically entered and no discriminatory ability (AUC = 0.47, 95% CI 0.16-0.84) where the basal cisterns had been surgically entered before ultrasound examination.

CONCLUSIONS

Automatically measured ONSD correlated well with ICP and displayed a perfect discriminatory ability in patients with aSAH in whom the basal cisterns had not been entered surgically before ultrasound examination, and may be a clinically valuable noninvasive marker of ICP in these patients. Caution should be exercised in using ONSD in patients in whom the basal cisterns have been entered surgically before ONSD measurements, as no association was observed in this subgroup.

Для цитирования: Netteland Dag Ferner, Aarhus Mads, Sandset Else Charlotte, Sorteberg Angelika, Padayachy Llewellyn, Helseth Eirik, Brekken Reidar. Real-Time Automated Measurements of Optic Nerve Sheath Diameter for Noninvasive Assessment of Intracranial Pressure in Aneurysmal Subarachnoid Hemorrhage.. Neurocritical care. 2025. DOI: 10.1007/s12028-024-02194-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.