MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2010.09.003

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2010

Ocular tolerance of a new multipurpose solution specifically formulated for daily wear of silicone hydrogel contact lenses.

Martin Raul, Rodriguez Guadalupe, de Juan Victoria, Fernandez Itziar, Sanchez Irene, de la Rosa Cristina, de Paz Isabel, Zalama Maria

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety, physiological performance, and effect on ocular tissues of a new multipurpose disinfecting solution (MPDS) specifically formulated for use with silicone hydrogel (SH) contact lenses (CL).

METHODS

Two MPDS [solution A (Solo-care Aqua(®), Ciba-Vision) and solution B (Hidro Health(®), Disop)] were randomly assigned and prescribed in a clinical trial in a crossover clinical trial (Registered #293/07/EC; Spanish National Health Department). Only lotrafilcon B CL daily wearers were included. After each solution was used, a masked investigator assessed the slit-lamp findings (SL9, Topcon Inc.), lens deposits, and wettability according to the Guidance for clinical investigation (ISO 11980). CL daily wearing time (hours per day and days per week) were recorded.

RESULTS

Fifty-four daily wearers were included. Average CL wear time was 8.3 ± 2.3 (CI95% 7.9-8.7) hours per day (8.5 ± 2.7 at baseline visit, 8.2 ± 1.9 with solution A, and 8.4 ± 2.2 with solution B). The average number of days per week of CL wear was 5.9 ± 1.3 (CI95% 5.6-6.1) (5.4 ± 1.6 at baseline visit, 6.1 ± 0.9 with solution A, and 6.0 ± 1.1 with solution B). Non-adverse slit-lamp findings were recorded (higher than 2 points). No statistical difference (P>0.05 Friedman test) in CL wearing time, number of days of CL wears and slit-lamp findings were found between the two solutions.

CONCLUSIONS

This clinical trial shows that the new formulation of Hidro Health(®) MPDS is safe when used for the care of daily-wear lotrafilcon B CL. This new solution has no clinical significance on ocular tissues, according to the Guidance for clinical investigation (ISO 11980).

Для цитирования: Martin Raul, Rodriguez Guadalupe, de Juan Victoria, Fernandez Itziar, Sanchez Irene, de la Rosa Cristina, de Paz Isabel, Zalama Maria. Ocular tolerance of a new multipurpose solution specifically formulated for daily wear of silicone hydrogel contact lenses.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2010. DOI: 10.1016/j.clae.2010.09.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.