MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20101001-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2010

Correlation among ocular spherical aberration, corneal spherical aberration, and corneal asphericity before and after LASIK for myopic astigmatism with the SCHWIND AMARIS platform.

Arba Mosquera Samuel, de Ortueta Diego

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the spherical wave aberration of the human eye based on corneal topography.

METHODS

Based on the pre- and postoperative status of 146 consecutive eyes (median patient age 36 years), the correlations between spherical aberration and asphericity and between corneal and ocular spherical aberrations were determined using simple linear regression methods. The asphericity (Q) values for which spherical aberration equals zero as well as the reference Q values for which corneal spherical aberration equals ocular spherical aberration have been determined. Patients underwent LASIK using the AMARIS excimer laser platform (SCHWIND eye-tech-solutions). All ablations were based on aspheric aberration-neutral profiles.

RESULTS

Corneal and ocular spherical aberrations correlate well with Q value and the value p · R(-3) in patients before and after LASIK for myopic astigmatism. A Q value of -0.19 to -0.27 can provide zero ocular spherical aberration in patients before and after LASIK for myopic astigmatism. Ocular spherical aberration is induced at a rate of half the induced corneal spherical aberration. A reference Q value of -0.12 to +0.01 can provide corneal spherical aberration equal to ocular spherical aberration in patients before and after LASIK for myopic astigmatism.

CONCLUSIONS

Ocular and corneal wave aberrations are two different concepts that are not interchangeable. As for spherical aberration, a simple static model with a reference cornea deviating from a Cartesian oval can provide a 2:1 correspondence between corneal and ocular spherical aberration.

Для цитирования: Arba Mosquera Samuel, de Ortueta Diego. Correlation among ocular spherical aberration, corneal spherical aberration, and corneal asphericity before and after LASIK for myopic astigmatism with the SCHWIND AMARIS platform.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2010. DOI: 10.3928/1081597x-20101001-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.