Corneal power measurement with a rotating Scheimpflug imaging system after Descemet-stripping automated endothelial keratoplasty.

Prasher Pawan, Muftuoglu Orkun, Bowman R Wayne, Cavanagh H Dwight, McCulley James P, Mootha V Vinod

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate alterations in corneal power parameters after Descemet-stripping automated endothelial keratoplasty (DSAEK) using rotating Scheimpflug imaging.

SETTING

University of Texas, Southwestern Medical Center, Dallas, Texas, USA.

METHODS

Eyes that had DSAEK were evaluated with a rotating Scheimpflug imaging system (Pentacam). The outcome parameters were mean anterior and posterior keratometry (K), mean anterior radius of curvature and posterior radius of curvature, anterior and posterior astigmatism, central corneal thickness (CCT), true net power, corneal volume, keratometric power deviation, and mean zonal-equivalent K readings. These values were compared with those in a control group of age and sex-matched normal eyes.

RESULTS

The DSAEK group comprised 32 eyes (28 patients) and the control group, 32 eyes. The mean anterior K, posterior K, and true net power were 42.53 diopters (D) +/- 1.52 (SD), -6.80 +/- 0.55 D, and 40.55 +/- 1.79 D, respectively, in the DSAEK group and 43.60 +/- 1.62 D, -6.20 +/- 0.31 D, and 42.49 +/- 1.57 D, respectively, in the control group. The posterior radius of curvature, anterior and posterior K values, and true net power were statistically significantly lower in DSAEK eyes than in control eyes (P<.01). The equivalent K readings were significantly lower in all zones in DSAEK eyes than in control eyes (P<.01). The mean CCT was significantly higher in DSAEK eyes than in control eyes (628 +/- 46 mum versus 553 +/- 35 mum) (P<.01).

CONCLUSION

The true net power of the cornea decreased significantly after DSAEK, mainly because of an increase in posterior curvature.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Prasher Pawan, Muftuoglu Orkun, Bowman R Wayne, Cavanagh H Dwight, McCulley James P, Mootha V Vinod. Corneal power measurement with a rotating Scheimpflug imaging system after Descemet-stripping automated endothelial keratoplasty.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2010.01.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.