MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181d0092c

Медицинская библиотека · Cornea · 2010

Comparison of anterior and posterior corneal surface irregularity in Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty.

Yamaguchi Takefumi, Negishi Kazuno, Yamaguchi Kazuko, Dogru Murat, Uchino Yuichi, Shimmura Shigeto, Tsubota Kazuo

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the irregularity of the anterior and posterior cornea after Descemet stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK).

METHODS

This clinical study comprised 39 eyes: 13 consecutive eyes after DSAEK, 13 consecutive eyes after PK, and 13 age-matched normal eyes. Corneal elevation data were acquired using a rotating Scheimpflug camera 1 and 3 months after DSAEK and PK. Anterior and posterior corneal elevation data were decomposed into a set of Zernike polynomials up to eighth order. Total higher-order root mean square (RMS) and RMS from third to eighth order were calculated. The astigmatism and irregularity of the anterior and posterior surfaces were compared between DSAEK and PK.

RESULTS

The regular astigmatism and tilt components of the anterior surface were significantly lower after DSAEK than after PK at 1 and 3 months (P < 0.001), whereas there was no difference in astigmatism of the posterior surface between the groups (P = 0.07, 0.22). The higher-order RMS and RMSs of third- to eighth-order components of the anterior surface were significantly larger after PK than those after DSAEK at 1 and 3 months (P < 0.01), whereas there were no significant differences between DSAEK and PK in higher-order aberration RMS and RMSs of third- to eighth-order components of the posterior surface.

CONCLUSIONS

Postoperative corneal irregularity of the anterior surface was greater after PK than after DSAEK, whereas there was no significant difference in posterior surface irregularity. DSAEK is superior to PK in terms of the higher-order irregularity of the anterior surface.

Для цитирования: Yamaguchi Takefumi, Negishi Kazuno, Yamaguchi Kazuko, Dogru Murat, Uchino Yuichi, Shimmura Shigeto, Tsubota Kazuo. Comparison of anterior and posterior corneal surface irregularity in Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty.. Cornea. 2010. DOI: 10.1097/ico.0b013e3181d0092c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.