Relationships Between Intestinal Ultrasound Parameters and Histopathologic Findings in a Prospective Cohort of Patients With Crohn's Disease Undergoing Surgery.

Allocca Mariangela, Dal Buono Arianna, D'Alessio Silvia, Spaggiari Paola, Garlatti Valentina, Spinelli Antonino, Faita Francesco, Danese Silvio

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Recognition of intestinal lesions with substantial fibrosis is strategic for optimal management of patients with Crohn's disease (CD). We aimed to assess the relationships between intestinal ultrasound parameters and histopathologic findings in a prospective cohort of patients with CD undergoing surgery.

METHODS

Seventeen consecutive adult CD patients with involvement of the terminal ileum or the sigmoid colon who underwent bowel resective surgeries were enrolled and performed intestinal ultrasound (IUS) within 30 days prior to surgery. Uni- and multivariable analyses were used to assess the relationships between IUS parameters and histopathological elements of lesions.

RESULTS

Sensitivity, specificity, accuracy, PPV and NPV (95% CI) of IUS in detecting stricturing and penetrating complications (surgical specimen as reference standard) were 93% (68-100), 86% (42-100), 91% (71-99), 93% (68-100) and 86% (42-100), and 78% (40-97), 92% (64-100), 86% (65-97), 88% (47-100) and 86% (57-98), respectively. Only the presence of hyperechogenic spiculates was statistically significantly associated with collagen content (b = 7.29, 95% CI = 1.88/12.69, P = .012), while only the presence of vascular signals at color Doppler (Limberg score 3 or 4) was significantly associated with active inflammation (OR = 10.0, 95% CI = 0.9/108.6, P = .037). There was a strong correlation between IUS and histological measurements of the wall thickness (r = 0.67, P = .01).

CONCLUSIONS

The presence of hyperechogenic spiculates was associated with the presence of fibrosis, while the presence of marked vascular signals was associated with the presence of inflammation. Wall thickness measured by IUS was reliable and reproducible in comparison with histological measurement.

Для цитирования: Allocca Mariangela, Dal Buono Arianna, D'Alessio Silvia, Spaggiari Paola, Garlatti Valentina, Spinelli Antonino, Faita Francesco, Danese Silvio. Relationships Between Intestinal Ultrasound Parameters and Histopathologic Findings in a Prospective Cohort of Patients With Crohn's Disease Undergoing Surgery.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2023. DOI: 10.1002/jum.16191.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.