Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice.

Palmisano Pietro, Iacopino Saverio, De Vivo Stefano, D'Agostino Carlo, Tomasi Luca, Startari Umberto, Ziacchi Matteo, Pisanò Ennio Carmine Luigi, Santobuono Vincenzo Ezio, Caccavo Vincenzo Paolo, Sgarito Giuseppe, Rillo Mariano, Nicosia Antonino, Zucchelli Giulio

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking.

METHODS

Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded.

RESULTS

A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) (n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, device migration in one patient.

CONCLUSIONS

In the real world setting of Italian clinical practice L-PM is often reserved for patients at high-risk of infection. The implantation success rate was very high and the risk of major complications was low. Peri-procedural management of OAT was consistent with available scientific evidence.

Для цитирования: Palmisano Pietro, Iacopino Saverio, De Vivo Stefano, D'Agostino Carlo, Tomasi Luca, Startari Umberto, Ziacchi Matteo, Pisanò Ennio Carmine Luigi, Santobuono Vincenzo Ezio, Caccavo Vincenzo Paolo, Sgarito Giuseppe, Rillo Mariano, Nicosia Antonino, Zucchelli Giulio. Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice.. International journal of cardiology. 2022. DOI: 10.1016/j.ijcard.2022.07.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.