Effect of Phacoemulsification on Sub Foveal Choroidal and Central Macular Thickness as measured by Swept Source Optical Coherence Tomography.
Аннотация
OBJECTIVES
To study the effect of Phacoemulsification on Sub Foveal Choroidal Thickness (SFCT) and Central Macular Thickness (CMT) as measured by Swept Source Optical Coherence Tomography (OCT).
METHODS
This experimental study was conducted at Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi from April 2021 to February 2022. One hundred eyes of 100 patients with age related cataract underwent uneventful phacoemulsification surgery. Pre-operative SFCT and CMT was measured and compared with SFCT and CMT at one week, one month and three months after surgery using swept source OCT.
RESULTS
Mean age of study population was 56.76±8.31 years. Out of 100 patients, 46 (46%) were males and 54 (54%) were females. Mean pre-operative CMT, one week, one month and three months post-operative CMT was 233.95±9.46 μm, 232.88±8.59 μm, 230.38±10.62 μm and 230.67±7.55 μm respectively. Mean pre-operative SFCT, one week, one month and three months post-operative SFCT was 337.14±8.41 μm, 339.14±9.63 μm, 339.39±11.96 μm and 351.39±9.19 μm respectively. The difference of mean change in CMT from baseline at one week, one month and three months post-operatively was not statistically significant. The difference of mean change in SFCT from baseline at one week and one month post-operatively was not statistically significant. However, the difference of mean change in SFCT from baseline at three months post-operatively was statistically significant (p<0.05).
CONCLUSION
Uneventful phacoemulsification surgery does not have any effect on central macular thickness, however there is a significant increase in subfoveal choroidal thickness at three months after surgery.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.