MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001253

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Choice of intraocular lens calculation formula for cataract patients with prior pars plana vitrectomy.

Zhang Jiaqing, Han Xiaotong, Chen Xiaoyun, Liu Zhenzhen, Zhang Yu, Qiu Xiaozhang, Tan Xuhua, Luo Lixia, Liu Yizhi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the optimal intraocular lens (IOL) calculation formula for vitrectomized eyes with diverse surgical and biometric characteristics.

SETTING

Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.

DESIGN

Retrospective consecutive case series study.

METHODS

This study included 974 vitrectomized eyes (974 patients) scheduled for phacoemulsification with IOL implantation. 11 formulas were evaluated: Barrett Universal II (BUII), Emmetropia Verifying Optical, Hoffer-QST, Kane, Ladas Super Formula, Pearl-DGS, Radial Basis Function (RBF), Haigis, HofferQ, Holladay1, and SRK/T. Risk factors for prediction error (PE) exceeding 1 diopter (D) were determined using multiple logistic regression. Subgroup analyses were performed based on surgical history and biometric parameters.

RESULTS

The risk of hyperopic PE (>1 D) was higher in patients with silicone oil tamponade (odds ratio [OR], 1.82) and longer axial length (AL) (OR, 1.55), while patients with previous scleral buckling (OR, 2.43) or ciliary sulcus IOL implantation (OR, 6.65) were more susceptible to myopic PE (<-1 D). The Kane formula had the highest overall prediction accuracy, and also the best in silicone oil-filled eyes and the flat cornea subgroup. The BUII and RBF displayed the optimal performance in eyes with previous scleral buckle and steep cornea, respectively. In eyes with an AL ≥ 26 mm, the Holladay1 with the nonlinear version of the Wang-Koch AL adjustment (Holladay1-WKn) showed the lowest absolute PE and highest percentage within ± 1.0 D of PE.

CONCLUSIONS

The Kane achieved the highest overall prediction accuracy in vitrectomized eyes. The optimal formula for eyes with previous scleral buckle, steep cornea, or long AL was BUII, RBF, and Holladay1-WKn, respectively.

Для цитирования: Zhang Jiaqing, Han Xiaotong, Chen Xiaoyun, Liu Zhenzhen, Zhang Yu, Qiu Xiaozhang, Tan Xuhua, Luo Lixia, Liu Yizhi. Choice of intraocular lens calculation formula for cataract patients with prior pars plana vitrectomy.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.