BACKGROUND

Robotic ventral hernia repair has been increasing globally, with comparable outcomes to laparoscopic repair and lower rates of conversion to open surgery. Robotic surgery is increasing in popularity, and there is a number of new robotic systems entering the marketing. We report the first case of a Roboic eTEP using the Versius robotic system in a patient with an incisional hernia.

METHODS

Surgery was performed using the Versius system from CMR surgical which consists of bedside units for each instrument and a console. The patient presented with an incisional hernia measuring 9.5×5 cm in the left flank.

RESULTS

The patient was discharged on postoperative day (POD) 2 with a drain. There was no need for opioids. The drain was removed at POD 7. The patient presented at POD 10 with erythema and cellulitis in the area that previously had tape on it, and it was resolved with a short course of oral antibiotics.

CONCLUSION

The eTEP technique for hernia surgery was safe and feasible using the Versius robotic system. Implementation is possible in experienced hands with minimal changes to the surgical techniques.

Для цитирования: Pinto Renato D, Trauczynski Pedro, Lima Diego L, Cavazzola Leandro T. Implementation of the Versius Surgical System in Complex Abdominal Wall Repair: First Reported Case of an Robotic ETEP/TAR Procedure.. Surgical laparoscopy, endoscopy & percutaneous techniques. 2024. DOI: 10.1097/sle.0000000000001231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.