Early Gains in Renal Function Following Implantation of HeartMate II Left Ventricular Assist Devices May Not Persist to One Year.

Hasin Tal, Grupper Avishay, Dillon John J, Maleszewski Joseph J, Li Zhuo, Topilsky Yan, Frantz Robert P, Edwards Brooks S, Pereira Naveen L, Maltais Simon, Stulak John M, Joyce Lyle, Daly Richard, Park Soon J, Kushwaha Sudhir S

СтатьяПеревод пока не подготовлен

Аннотация

Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = -0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.

Для цитирования: Hasin Tal, Grupper Avishay, Dillon John J, Maleszewski Joseph J, Li Zhuo, Topilsky Yan, Frantz Robert P, Edwards Brooks S, Pereira Naveen L, Maltais Simon, Stulak John M, Joyce Lyle, Daly Richard, Park Soon J, Kushwaha Sudhir S. Early Gains in Renal Function Following Implantation of HeartMate II Left Ventricular Assist Devices May Not Persist to One Year.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2017. DOI: 10.1097/mat.0000000000000511.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.