An ultra performance liquid chromatography method for transthyretin variants screening and heart failure assisting diagnosis.
Аннотация
BACKGROUND
Transthyretin (TTR) gene mutations are associated with hereditary amyloidosis (ATTR) caused by mutant TTR protein dissociation, misfolding, aggregation, and insoluble fibrils deposition. Herein, we reported a chromatographic approach for quantification and identification of TTR tetramer in human blood serum by ultra performance liquid chromatography (UPLC).
METHODS
TTR proteins and serum were incubated with a fluorescent TTR tetramer sensor (A2). The A2 sensor specifically reacted with tetrameric TTR and released stoichiometric fluorescence that was detected by fluorescence detector coupled to UPLC. The external standard was used for quantification, the chromatographic peak parameters were used to identification certain mutation types.
RESULTS
UPLC correctly distinguished 18 types of mutant TTR proteins from wild type. The results were consistent with follow-up analysis of two ATTR patients' blood serum samples. In addition, the tetrameric TTR of 30 heart failure (HF) patients showed strongly correlation (r = -0.63, p < 0.00) with NT-proBNP, a HF clinical biomarker.
CONCLUSIONS
UPLC method has sufficient accuracy to eliminate the necessity of sequencing for certain types of TTR mutations and allows for facile initial screening of ATTR amyloidosis patients, carriers, and healthy individuals for time-saving and economical purposes. TTR tetramer may serve as a diagnostic biomarker to evaluate the risk of HF diseases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.