DOI 10.3928/1081597x-20180831-01
Initial Clinical Results With a Novel Monofocal-Type Intraocular Lens for Extended Macular Vision in Patients With Macular Degeneration.
Аннотация
PURPOSE: To determine the feasibility of a novel intraocular lens (IOL) designed to improve retinal image quality at up to 10° of retinal eccentricity and optionally provide retinal magnification in patients with macular disease.
METHODS
In this prospective, interventional pilot study, 8 eyes of 7 patients with bilateral dry age-related macular degeneration and 1+ or less cataract underwent phacoemulsification and capsular bag implantation of a single, injectable, hydrophobic acrylic IOL. Safety and efficacy were assessed by monitoring logMAR corrected distance and near visual acuity, intraocular pressure, specular microscopy, 80-point visual field testing, and anterior segment and macular optical coherence tomography at baseline and 1 week, 1 month, and 2 months postoperatively. Microperimetry was undertaken at baseline and 1 and/or 2 months postoperatively. Reading performance was assessed at baseline and 1 month postoperatively using the Minnesota low vision reading chart (MNREAD; Precision Vision, LaSalle, IL).
RESULTS
Safety outcomes were equivalent to standard monofocal IOLs. Visual acuities improved in all patients. Mean corrected distance visual acuity improved from 0.93 ± 0.22 preoperatively to 0.59 ± 0.25 at 2 months postoperatively. Mean reading speed increased from 28 ± 19 to 44 ± 31 words per minute. Mean microperimetry threshold sensitivities increased from 8.2 ± 4.6 to 12 ± 5.6 dB. Mean percentage of fixation points within a 4° circle increased from 77% ± 17% to 91% ± 11% with evidence for progressive movement of preferred retinal loci away from areas of geographic atrophy.
CONCLUSIONS
Initial results indicate this novel IOL has a safety profile comparable with standard IOLs. Visual benefits may exceed those obtained with existing technologies in patients with macular disease. Further work is required to determine the full potential of extended macular vision technology. [J Refract Surg. 2018;34(11):718-725.].
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.