Complex Re-Entrant Arrhythmias Involving the His-Purkinje System: A Structured Approach to Diagnosis and Management.

Voskoboinik Aleksandr, Gerstenfeld Edward P, Moss Joshua D, Hsia Henry, Goldberger Jeffrey, Nazer Babak, Dewland Thomas, Singh David, Badhwar Nitish, Tchou Patrick J, Meriwether John N, Sauer William, Danon Asaf, Belhassen Bernard, Scheinman Melvin M

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to characterize the presentations, electrophysiological features and diagnostic maneuvers for a series of unique arrhythmias involving the HPS.

BACKGROUND

By virtue of its unique anatomy and ion channel composition, the His-Purkinje system (HPS) is prone to a variety of arrhythmic perturbations.

METHODS

The authors present a collaborative multicenter case series of 6 patients with HPS-related arrhythmias. All patients underwent electrophysiological studies using standard multipolar catheters.

RESULTS

In 3 patients, both typical and reverse bundle branch re-entry were seen, with 1 patient demonstrating "figure of 8" re-entry likely involving the septal fascicle. One patient presented with systolic dysfunction associated with a high premature ventricular complex burden, with the mechanism being bundle-to-bundle re-entrant beats masquerading as dual response to a single sinus impulse. Two patients were diagnosed with interfascicular re-entry. Diagnosis was aided by careful assessment of HV interval in sinus rhythm and ventricular tachycardia, multipolar catheters to assess the activation sequence of the His-right bundle branch, and fascicles and entrainment of different components of the HPS. Cure of the arrhythmia was achieved by ablation of the right bundle branch block in 3 patients, the left septal fascicle in 2 patients, and the left posterior fascicle in 1 patient.

CONCLUSIONS

Proper diagnosis of re-entrant arrhythmias involving the HPS may prove challenging. We emphasize a structured approach for diagnosis and effective therapy.

Для цитирования: Voskoboinik Aleksandr, Gerstenfeld Edward P, Moss Joshua D, Hsia Henry, Goldberger Jeffrey, Nazer Babak, Dewland Thomas, Singh David, Badhwar Nitish, Tchou Patrick J, Meriwether John N, Sauer William, Danon Asaf, Belhassen Bernard, Scheinman Melvin M. Complex Re-Entrant Arrhythmias Involving the His-Purkinje System: A Structured Approach to Diagnosis and Management.. JACC. Clinical electrophysiology. 2020. DOI: 10.1016/j.jacep.2020.06.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.