The effects of transcatheter aortic valve implantation on cardiac electrical properties.

Manuel Ana Mosalina, Almeida João, Guerreiro Cláudio, Dias Tiago, Barbosa Ana, Teixeira Pedro, Ribeiro José, Dias Adelaide, Caeiro Daniel, Fonseca Marlene, Teixeira Madalena, Oliveira Marco, Gonçalves Helena, Primo João, Rodrigues Alberto, Gama Vasco, Braga Pedro, Fontes-Carvalho Ricardo

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Transcatheter aortic valve implantation (TAVI) is associated with cardiac electrical disturbances. However, beyond the risks of pacemaker implantation, few studies have performed a detailed assessment of the effects of TAVI on several cardiac electrical properties.

OBJECTIVES

To assess the frequency and type of electrocardiographic disturbances following TAVI, according to the type of prostheses and to assess predictors of these disturbances.

METHODS

We performed a detailed retrospective analysis of all electrocardiograms in patients who underwent TAVI, before and after the procedure, at a tertiary center from August 2007 to October 2016. Patients with permanent pacemakers were excluded.

RESULTS

We included 182 patients (78±8 years; 56% female) and self-expanding prostheses (SEP) were implanted in 54%. Most patients (80%) were in sinus rhythm at baseline. After TAVI, 21% of patients developed new-onset atrial fibrillation and there was a significant increase in PR interval at discharge (186±41 ms vs. 176±32; p=0.003), which was not maintained after at six-month follow-up (181±35 ms, p=0.06). There was also a significant increase in QRS duration at discharge (129±28 ms vs. 114±25 at baseline p<0.0001), which persisted at six-months (122±28 ms, p<0.0001). New-onset left-bundle branch block (LBBB) was observed in 25% of patients. The depth of valve implantation was a predictor of new LBBB at discharge after multivariate analysis (OR 37.6, 95% CI 14.6-65.2, p=0.001).

CONCLUSIONS

The main electrocardiographic disturbances post TAVI were PR prolongation, increased QRS and new-onset LBBB. These disturbances were more pronounced in patients undergoing SEP implantation and tended to improve at six-month follow-up. The depth of valve implantation was a predictor of conduction disturbances.

Для цитирования: Manuel Ana Mosalina, Almeida João, Guerreiro Cláudio, Dias Tiago, Barbosa Ana, Teixeira Pedro, Ribeiro José, Dias Adelaide, Caeiro Daniel, Fonseca Marlene, Teixeira Madalena, Oliveira Marco, Gonçalves Helena, Primo João, Rodrigues Alberto, Gama Vasco, Braga Pedro, Fontes-Carvalho Ricardo. The effects of transcatheter aortic valve implantation on cardiac electrical properties.. Revista portuguesa de cardiologia. 2020. DOI: 10.1016/j.repc.2020.02.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.