DOI 10.1016/j.hrthm.2020.05.036
Preimplantation interlead ECG heterogeneity is superior to QRS complex duration in predicting mechanical super-response in patients with non-left bundle branch block receiving cardiac resynchronization therapy.
Аннотация
BACKGROUND
Reliable quantitative preimplantation predictors of response to cardiac resynchronization therapy (CRT) are needed.
OBJECTIVE
We tested the utility of preimplantation R-wave and T-wave heterogeneity (RWH and TWH, respectively) compared to standard QRS complex duration in identifying mechanical super-responders to CRT and mortality risk.
METHODS
We analyzed resting 12-lead electrocardiographic recordings from all 155 patients who received CRT devices between 2006 and 2018 at our institution and met class I and IIA American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines with echocardiograms before and after implantation. Super-responders (n=35, 23%) had ≥20% increase in left ventricular ejection fraction and/or ≥20% decrease in left ventricular end-systolic diameter and were compared with non-super-responders (n=120, 77%), who did not meet these criteria. RWH and TWH were measured using second central moment analysis.
RESULTS
Among patients with non-left bundle branch block (LBBB), preimplantation RWH was significantly lower in super-responders than in non-super-responders in 3 of 4 lead sets (P=.001 to P=.038) and TWH in 2 lead sets (both, P=.05), with the corresponding areas under the curve (RWH: 0.810-0.891, P<.001; TWH: 0.759-0.810, P≤.005). No differences were observed in the LBBB group. Preimplantation QRS complex duration also did not differ between super-responders and non-super-responders among patients with (P=.856) or without (P=.724) LBBB; the areas under the curve were nonsignificant (both, P=.69). RWHV1-3LILII ≥ 420 μV predicted 3-year all-cause mortality in the entire cohort (P=.037), with a hazard ratio of 7.440 (95% confidence interval 1.015-54.527; P=.048); QRS complex duration ≥ 150 ms did not predict mortality (P=.27).
CONCLUSION
Preimplantation interlead electrocardiographic heterogeneity but not QRS complex duration predicts mechanical super-response to CRT in patients with non-LBBB.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.