MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cjca.2020.05.011

Медицинская библиотека · The Canadian journal of cardiology · 2020

Simplifying Physiological Left Bundle Branch Area Pacing Using a New Nine-Partition Method.

Zhang Junmeng, Wang Zefeng, Zu Linna, Cheng Liting, Su Ruijuan, Wang Xinlu, Liang Zhuo, Chen Jieruo, Hang Fei, Du Jie, Huang Weijian, Wu Yongquan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Left bundle branch area pacing (LBBaP) is accepted as a physiological form of pacing; however, it is complex and usually requires an expensive electrophysiological recording system.

METHODS

A simplified approach ("9-partition method") was explored to perform LBBaP. In this method, a right anterior oblique 30° fluoroscopic image of the ventricle was divided into 9 sections ("3 × 3" partitions). From May 2018 to February 2019, we enrolled 51 consecutive patients who underwent pacemaker implantation. The patients were nonrandomly allocated to either the conventional LBBaP (c-LBBaP) group or simplified LBBaP (s-LBBaP) group.

RESULTS

The mean age was 68.53 ± 11.90 years, and 32 (62.7%) patients were male. The overall success rate was 90.2% (46/51). Compared with the c-LBBaP group, the s-LBBaP group had a significantly lower total procedure duration (91.57 ± 19.51 minutes vs 70.68 ± 13.26 minutes; P < 0.001) and fluoroscopy duration (16.52 ± 5.34 minutes vs 10.54 ± 3.13 minutes; P < 0.001). The time from the 3830 lead and sheath passage through the tricuspid valve to an acceptable initial fixation site (4.69 ± 1.61 minutes vs 2.75 ± 1.04 minutes; P < 0.001) and the time to the left bundle branch lead being implanted successfully (11.78 ± 3.00 minutes vs 7.67 ± 2.45 minutes; P < 0.001) for the c-LBBaP vs s-LBBaP groups, respectively, were significantly different. After 3 months, there were no significant differences in the capture threshold, R wave amplitude, impedance, or QRS duration between the groups.

CONCLUSIONS

Compared with the c-LBBaP approach, our simplified 9-partition method was faster and did not require an expensive electrophysiological recording system.

Для цитирования: Zhang Junmeng, Wang Zefeng, Zu Linna, Cheng Liting, Su Ruijuan, Wang Xinlu, Liang Zhuo, Chen Jieruo, Hang Fei, Du Jie, Huang Weijian, Wu Yongquan. Simplifying Physiological Left Bundle Branch Area Pacing Using a New Nine-Partition Method.. The Canadian journal of cardiology. 2020. DOI: 10.1016/j.cjca.2020.05.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.