MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-018-0746-z

Медицинская библиотека · Japanese journal of radiology · 2018

Differentiation of benign and malignant ampullary obstruction by multi-row detector CT.

Angthong Wirana, Jiarakoop Kran, Tangtiang Kaan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine useful CT parameters to differentiate ampullary carcinomas from benign ampullary obstruction.

MATERIALS AND

METHODS

This study included 93 patients who underwent abdominal CT, 31 patients with ampullary carcinomas, and 62 patients with benign ampullary obstruction. Two radiologists independently evaluated CT parameters then reached consensus decisions. Statistically significant CT parameters were identified through univariate and multivariate analyses.

RESULTS

In univariate analysis, the presence of ampullary mass, asymmetric, abrupt narrowing of distal common bile duct (CBD), dilated intrahepatic bile duct (IHD), dilated pancreatic duct (PD), peripancreatic lymphadenopathy, duodenal wall thickening, and delayed enhancement were more frequently in ampullary carcinomas observed (P < 0.05). Multivariate logistic regression analysis using significant CT parameters and clinical data from univariate analysis, and clinical symptom with jaundice (P = 0.005) was an independent predictor of ampullary carcinomas. For multivariate analysis using only significant CT parameters, abrupt narrowing of distal CBD was an independent predictor of ampullary carcinomas (P = 0.019). Among various CT criteria, abrupt narrowing of distal CBD and dilated IHD had highest sensitivity (77.4%) and highest accuracy (90.3%).

CONCLUSION

The abrupt narrowing of distal CBD and dilated IHD is useful for differentiation of ampullary carcinomas from benign entity in patients without the presence of mass.

Для цитирования: Angthong Wirana, Jiarakoop Kran, Tangtiang Kaan. Differentiation of benign and malignant ampullary obstruction by multi-row detector CT.. Japanese journal of radiology. 2018. DOI: 10.1007/s11604-018-0746-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.