DOI 10.3760/cma.j.cn112142-20231211-00282

Медицинская библиотека · [Zhonghua yan ke za zhi] Chinese journal of ophthalmology · 2024

[Clinical observation of the intraocular distribution characteristics of indocyanine green after epiretinal membrane peeling using a fluorescence detection system developed in Python].

Zhang Y, Zhang K R, Gao S, Zhang M X

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

Objective

To utilize a Python-based fluorescence area detection system to observe and quantitatively analyze the intraocular distribution characteristics and metabolic patterns of Indocyanine Green (ICG) following epiretinal membrane peeling.

Methods

A prospective case series study was conducted on patients with idiopathic epiretinal membrane undergoing vitrectomy at West China Hospital of Sichuan University from March 2019 to March 2021. ICG staining was applied during surgery for peeling the epiretinal membrane and internal limiting membrane. Patients were followed up at 1 week, 1 month, 3 months, 6 months, and 12 months postoperatively, with assessments including best-corrected visual acuity, intraocular pressure, fundus photography, near-infrared fundus fluorescence imaging (NIR-FF), and optical coherence tomography (OCT). A Python-based ICG intraocular metabolism detection system was developed to measure the residual area of ICG fluorescence on NIR-FF, predict the ICG metabolic pattern equation, and correlate it with postoperative visual acuity and peripapillary retinal nerve fiber layer thickness.

Results

A total of 64 patients (64 eyes) were included, with an average age of 64.6±8.4 years, including 25 males (39.1%) and 39 females (60.9%). Preoperative NIR-FF images showed no ICG strong fluorescence. At 1 week postoperatively, diffuse ICG strong fluorescence appeared in the posterior pole, and the internal limiting membrane removal area exhibited a ring-like weak fluorescence. Over time, ICG strong fluorescence was observed along the vascular arch and nerve fiber trajectory, gradually diminishing toward the optic disc, with residual ICG fluorescence still visible at the optic disc at 1 year. The Python-based ICG fluorescence area detection system effectively measured intraocular residual ICG area. A predictive equation for the 12-month residual ICG area was constructed through linear regression analysis (Residual ICG area=0.22 × Residual ICG area at 6 months, R2=16%, P=0.002). Except for a negative correlation between the ICG residual area at 1 month and postoperative visual acuity (P=0.017, r=-0.195), no correlation was found between intraocular ICG fluorescence residual area and postoperative visual acuity or peripapillary retinal nerve fiber layer thickness at other follow-up times (all P>0.05).

Conclusions

In patients with idiopathic epiretinal membrane undergoing ICG staining for internal limiting membrane peeling, ICG exhibits characteristic metabolic processes in the eye, with strong fluorescence along the vascular arch and nerve fiber trajectory, gradually converging toward the optic disc over time. The Python-based ICG fluorescence area detection system provides a clear display of the intraocular distribution characteristics of ICG after epiretinal membrane peeling and serves as a tool for predicting the metabolic patterns of ICG in the eye.

Для цитирования: Zhang Y, Zhang K R, Gao S, Zhang M X. [Clinical observation of the intraocular distribution characteristics of indocyanine green after epiretinal membrane peeling using a fluorescence detection system developed in Python].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2024. DOI: 10.3760/cma.j.cn112142-20231211-00282.