MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08820538.2024.2324074

Медицинская библиотека · Seminars in ophthalmology · 2024

Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function.

Leal-Vega Luis, Piñero David P, Molina-Martín Ainhoa, Hernández-Rodríguez Carlos J, Cuadrado-Asensio Rubén, Martín-Gutiérrez Adrián, Arenillas Lara Juan Francisco, Coco Martín María Begoña

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults.

METHODS

Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.

RESULTS

Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (p = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (p = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain.

CONCLUSION

Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.

Для цитирования: Leal-Vega Luis, Piñero David P, Molina-Martín Ainhoa, Hernández-Rodríguez Carlos J, Cuadrado-Asensio Rubén, Martín-Gutiérrez Adrián, Arenillas Lara Juan Francisco, Coco Martín María Begoña. Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function.. Seminars in ophthalmology. 2024. DOI: 10.1080/08820538.2024.2324074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.