MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mbp.0b013e3283353199

Медицинская библиотека · Blood pressure monitoring · 2010

Using the Finometer to examine sex differences in hemodynamic responses to orthostasis in older people.

Romero-Ortuno Roman, Cogan Lisa, Foran Tim, Fan Chie Wei, Kenny Rose Anne

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

In young and middle age, women have higher orthostatic intolerance (OI) than men, and hemodynamic differences have been found supporting this finding. In older people, these sex differences are less studied. Our aim was to contribute evidence.

METHODS

Two hundred and twenty-four community-dwelling older participants were studied (154 females and 70 males, mean age 72.6, standard deviation 7.3) who were without dementia or risk factors for autonomic neuropathy. Men and women were well matched for baseline characteristics. Finometer Pro was used to noninvasively monitor participants during an active stand test. Derived hemodynamic parameters were extracted with BeatScope (5-s averages method) at different phases (baseline, nadir, and recovery at 2 minutes), and compared between men and women. OI symptoms were recorded. Subgroup analyses were conducted focusing on the presence or absence of antihypertensives.

RESULTS

Men and women did not differ in OI. Men tended to drop to a lower nadir (117 vs. 128 mmHg, P=0.001) and reach lower recovery systolic blood pressure than women (161 vs. 171 mmHg, P=0.006); Women had greater total peripheral resistance (P<0.001) and a trend towards lower stroke volumes (P<0.01). However, these differences disappeared in the nonmedicated subgroup. Consistently, women had greater aortic impedance and lower arterial compliance (P<0.001), suggesting greater arterial stiffness.

CONCLUSION

The Finometer is a useful tool to monitor orthostatic hemodynamics in older people, and in this study it allowed establishment of interesting sex differences. For further understanding, validation of Modelflow-derived parameters against other clinical standards is desirable.

Для цитирования: Romero-Ortuno Roman, Cogan Lisa, Foran Tim, Fan Chie Wei, Kenny Rose Anne. Using the Finometer to examine sex differences in hemodynamic responses to orthostasis in older people.. Blood pressure monitoring. 2010. DOI: 10.1097/mbp.0b013e3283353199.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.