MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-023-03958-2

Медицинская библиотека · Abdominal radiology (New York) · 2023

The efficacy of low-dose CT with deep learning image reconstruction in the surveillance of incidentally detected pancreatic cystic lesions.

Koh Sungho, Lee Nam Kyung, Kim Suk, Hong Seung Baek, Kim Dong Uk, Han Sung Yong

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy of low-dose CT (LDCT) with deep learning image reconstruction (DLIR) for the surveillance of pancreatic cystic lesions (PCLs) compared with standard-dose CT (SDCT) with adaptive statistical iterative reconstruction (ASIR-V).

METHODS

The study enrolled 103 patients who underwent pancreatic CT for follow-up of incidentally detected PCLs. The CT protocol included LDCT in the pancreatic phase with 40% ASIR-V, DLIR at medium (DLIR-M) and high levels (DLIR-H), and SDCT in the portal-venous phase with 40% ASIR-V. The overall image quality and conspicuity of PCLs were qualitatively assessed using five-point scales by two radiologists. The size of PCLs, presence of thickened/enhancing walls, enhancing mural nodules, and main pancreatic duct dilatation were reviewed. CT noise and cyst-to-pancreas contrast-to-noise ratio (CNR) were measured. Qualitative and quantitative parameters were analyzed using the chi-squared test, one-way ANOVA, and t-test. Additionally, interobserver agreement was analyzed using the kappa and weighted-kappa statistics.

RESULTS

The volume CT dose-indexes in LDCT and SDCT were 3.0 ± 0.6 mGy and 8.4 ± 2.9 mGy, respectively. LDCT with DLIR-H showed the highest overall image quality, the lowest noise, and the highest CNR. The PCL conspicuity in LDCT with either DLIR-M or DLIR-H was not significantly different from that in SDCT with ASIR-V. Other findings depicting PCLs also revealed no significant differences between LDCT with DLIR and SDCT with ASIR-V. Moreover, the results revealed good or excellent interobserver agreement.

CONCLUSION

LDCT with DLIR has a comparable performance with SDCT for the follow-up of incidentally detected PCLs.

Для цитирования: Koh Sungho, Lee Nam Kyung, Kim Suk, Hong Seung Baek, Kim Dong Uk, Han Sung Yong. The efficacy of low-dose CT with deep learning image reconstruction in the surveillance of incidentally detected pancreatic cystic lesions.. Abdominal radiology (New York). 2023. DOI: 10.1007/s00261-023-03958-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.