MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics11112098

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2021

Comparative Analysis of BIOCHIP Mosaic-Based Indirect Immunofluorescence with Enzyme-Linked Immunosorbent Assay for Diagnosing Myasthenia Gravis.

Gambino Caterina Maria, Agnello Luisa, Lo Sasso Bruna, Scazzone Concetta, Giglio Rosaria Vincenza, Candore Giuseppina, Ciaccio Anna Maria, Di Stefano Vincenzo, Brighina Filippo, Vidali Matteo, Ciaccio Marcello

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The detection of anti-acetylcholine receptor (AChR) and anti-muscle-specific tyrosine kinase (MuSK) antibodies is useful in myasthenia gravis (MG) diagnosis and management. BIOCHIP mosaic-based indirect immunofluorescence is a novel analytical method, which employs the simultaneous detection of anti-AChR and anti-MuSK antibodies in a single miniature incubation field. In this study, we compare, for the first time, the BIOCHIP MG mosaic with conventional enzyme-linked immunosorbent assay (ELISA) in the diagnosis of MG.

METHODS

A total of 71 patients with MG diagnosis were included in the study. Anti-AChR and anti-MuSK antibodies were measured separately by two different ELISA and simultaneously by BIOCHIP. The results were then compared.

RESULTS

The overall concordance between ELISA and BIOCHIP for anti-AChR reactivity was 74%. Cohen's kappa was 0.51 (95% CI 0.32-0.71), which corresponds to 90% of the maximum possible kappa (0.57), given the observed marginal frequencies. The overall concordance for anti-MuSK reactivity was 84%. Cohen's kappa was 0.11 (95% CI 0.00-0.36), which corresponds to 41% of the maximum possible kappa (0.27).

CONCLUSION

The overall concordance among assays is not optimal.

Для цитирования: Gambino Caterina Maria, Agnello Luisa, Lo Sasso Bruna, Scazzone Concetta, Giglio Rosaria Vincenza, Candore Giuseppina, Ciaccio Anna Maria, Di Stefano Vincenzo, Brighina Filippo, Vidali Matteo, Ciaccio Marcello. Comparative Analysis of BIOCHIP Mosaic-Based Indirect Immunofluorescence with Enzyme-Linked Immunosorbent Assay for Diagnosing Myasthenia Gravis.. Diagnostics (Basel, Switzerland). 2021. DOI: 10.3390/diagnostics11112098.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.