MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mus.26999

Медицинская библиотека · Muscle & nerve · 2020

Sensitivity and specificity of repetitive nerve stimulation with lower cutoffs for abnormal decrement in myasthenia gravis.

Lamb Christopher J, Rubin Devon I

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The sensitivity of repetitive nerve stimulation (RNS) in myasthenia gravis (MG) is dependent on the cutoff for abnormal decrement.

METHODS

RNS data of adults with and without MG from 2014 to 2017 were reviewed retrospectively. The maximum reliable RNS amplitude/area decrement before and after exercise from facial, spinal accessory (SA), ulnar, and fibular nerves was recorded. Sensitivity/specificity using 5%, 7%, and 10% cutoffs were calculated.

RESULTS

Seventy-nine of 141 patients had MG (46 generalized, 21 ocular, 12 bulbar). A total of 608 unique RNS recordings were analyzed. Overall RNS sensitivity/specificity at ≥5%, ≥7%, and ≥10% amplitude cutoffs were as follows: SA, 65.6%/86.3%, 49.2%/94.1%, and 29.5%/96.1%; facial, 51.0%/82.5%, 43.1%/95.0%, and 37.3%/100%; ulnar, 43.6%/100%, 41.0%/100%, and 41.0%/100%; and fibular, 52.6%/89.5%, 42.1%/94.7%, and 42.1%/100%.

DISCUSSION: Lowering amplitude cutoff from 10% to 7% increased or maintained sensitivity with little loss in specificity. Post-exercise and area analysis resulted in increased sensitivity in some circumstances.

Для цитирования: Lamb Christopher J, Rubin Devon I. Sensitivity and specificity of repetitive nerve stimulation with lower cutoffs for abnormal decrement in myasthenia gravis.. Muscle & nerve. 2020. DOI: 10.1002/mus.26999.