Temporal summation of repetitive click stimuli.

Darling R M, Price L L

СтатьяПеревод пока не подготовлен

Аннотация

Monaural loudness balances were performed by eight normal-hearing subjects to determine the effect of click repetition rate on loudness sensation. Click trains of 500 msec duration were matched in loudness to a standard 500 msec 1000 Hz tone burst presented at three reference loudness levels (70, 80, and 90 phons). Click trains were presented at repetition rates of 11, 31, 51, and 91 clicks per sec. It was found that click trains at faster repetition rates required lower intensities for judgments of equal loudness sensation. This finding was attributed to the process of temporal loudness summation. The magnitude and nature of the temporal summation process as well as the influence of the reference loudness level are discussed.

Для цитирования: Darling R M, Price L L. Temporal summation of repetitive click stimuli.. Ear and hearing. 1989. DOI: 10.1097/00003446-198906000-00006.