MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vox.13289

Медицинская библиотека · Vox sanguinis · 2022

Haemoglobin S testing using HEA BeadChip™ technology: Lifeblood comparison with clinical diagnosis.

Wong Philip, Baidya Shoma, Daly James, Powley Tanya

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Red cell antigen genotyping is commonly performed on patients requiring chronic transfusion support, such as sickle cell disease and thalassaemia. The Immucor HEA BeadChip™ test, in addition to assessing red cell antigen expression, can also detect the haemoglobin S (HbS) mutation. Our aim was to compare HbS results using HEA BeadChip™ performed at the Australian Red Cross Lifeblood with conventional haemoglobin studies.

MATERIALS AND

METHODS

Patients with thalassaemia and sickle cell trait (SCT) or disease (SCD) referred for red cell genotyping between 2017 and 2019 were assessed. The HbS result obtained from HEA BeadChip™ was compared with that obtained from high-performance liquid chromatography (HPLC) performed by the referring pathology provider.

RESULTS

One-hundred and nineteen cases had comparable HPLC and HEA BeadChip™ results. On HEA BeadChip™ testing, 40 cases showed a negative HbS result, 31 cases showed HbS+ and 47 cases showed HbS++. There was one case with 'low signal' result. Of the negative HbS cases, there was none with SCT. The HbS+ group comprised a mixture of SCT and SCD due to compound heterozygosity for HbS and β-thalassaemia mutations. The HbS++ group comprised predominantly SCD due to homozygosity for HbS.

CONCLUSION

HEA BeadChip™ is an accurate screening test for the detection of HbS. There were no false positives or false negatives. The identification of donors with the HbS mutation through the targeted genotyping programme would enable early intervention, improved donor management and reduced wastage.

Для цитирования: Wong Philip, Baidya Shoma, Daly James, Powley Tanya. Haemoglobin S testing using HEA BeadChip™ technology: Lifeblood comparison with clinical diagnosis.. Vox sanguinis. 2022. DOI: 10.1111/vox.13289.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.