MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s004020000230

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2001

Immunohistochemical characterization of the perivascular infiltrate cells in tissues adjacent to stainless steel implants compared with titanium implants.

Thewes M, Kretschmer R, Gfesser M, Rakoski J, Nerlich M, Borelli S, Ring J

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Metallic orthopaedics implants are composed of elements that are known to be skin sensitizers in the general population. In this study, we analyzed the cells of perivascular infiltration in the tissue adjacent to titanium (n = 23) and steel (n = 8) implants after explantation of the metals by immunohistochemical methods. The following panel of monoclonal antibodies were used as parameters: CD 1a (Langerhans cells), CD 4 (T-helper cells), CD 8 (T-suppressor cells), CD 11c (monocytes and macrophages), CD 45 RO (memory cells), CD 45 RA (naive cells), eosinophil cationic proteins (ECP), neutrophil elastase, and HLA-DR. The number of perivascular total cells did not differ significantly. All cells were identified in both metal subgroups, but a statistical difference was not seen in the above-mentioned parameters. We conclude that sensitization to metals is possible in the tissue adjacent to steel and titanium implants, because all cells which play an important role in allergic delayed-type hypersensitivity (type IV) reactions are present. This phenomenon may be called a 'pre-sensitization' phase, because no sensitization or allergic reactions were seen in our cases. Second, in the present study, a statistical difference was not seen in the number of infiltrate cells in the tissue adjacent to steel compared with titanium implants.

Для цитирования: Thewes M, Kretschmer R, Gfesser M, Rakoski J, Nerlich M, Borelli S, Ring J. Immunohistochemical characterization of the perivascular infiltrate cells in tissues adjacent to stainless steel implants compared with titanium implants.. Archives of orthopaedic and trauma surgery. 2001. DOI: 10.1007/s004020000230.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.