MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.119.008640

Медицинская библиотека · Circulation. Cardiovascular interventions · 2020

DISENGAGE Registry.

Pellicano Mariano, Ciccarelli Giovanni, Xaplanteris Panagiotis, Di Gioia Giuseppe, Milkas Anastasios, Colaiori Iginio, Heyse Alex, Van Durme Frederik, Vanderheyden Marc, Bartunek Jozef, De Bruyne Bernard, Barbato Emanuele

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

During fractional flow reserve (FFR) measurement, the simple presence of the guiding catheter (GC) within the coronary ostium might create artificial ostial stenosis, affecting the hyperemic flow. We aimed to investigate whether selective GC engagement of the coronary ostium might impede hyperemic flow, and therefore impact FFR measurements and related clinical decision-making.

METHODS

In the DISENGAGE (Determination of Fractional Flow Reserve in Intermediate Coronary Stenosis With Guiding Catheter Disengagement) registry, FFR was prospectively measured twice (with GC engaged [FFReng] and disengaged [FFRdis]) in 202 intermediate stenoses of 173 patients. We assessed (1) whether ΔFFReng-FFRdis was significantly different from the intrinsic variability of repeated FFR measurements (test-retest repeatability); (2) whether the extent of ΔFFReng-FFRdis could be clinically significant and therefore able to impact clinical decision-making; and (3) whether ΔFFReng-FFRdis related to the stenosis location, that is, proximal and middle versus distal coronary segments.

RESULTS

Overall, FFR significantly changed after GC disengagement: FFReng 0.84±0.08 versus FFRdis 0.80±0.09, P<0.001. Particularly, in 38 stenoses (19%) with FFR values in the 0.81 to 0.85 range, GC disengagement was associated with a shift from above to below the 0.80 clinical cutoff, resulting into a change of the treatment strategy from medical therapy to percutaneous coronary intervention. The impact of GC disengagement was significantly more pronounced with stenoses located in proximal and middle as compared with distal coronary segments (ΔFFReng-FFRdis, proximal and middle 0.04±0.03 versus distal segments 0.03±0.03; P=0.042).

CONCLUSIONS

GC disengagement results in a shift of FFR values from above to below the clinical cutoff FFR value of 0.80 in 1 out of 5 measurements. This occurs mostly when the stenosis is located in proximal and middle coronary segments and the FFR value is close to the cutoff value.

Для цитирования: Pellicano Mariano, Ciccarelli Giovanni, Xaplanteris Panagiotis, Di Gioia Giuseppe, Milkas Anastasios, Colaiori Iginio, Heyse Alex, Van Durme Frederik, Vanderheyden Marc, Bartunek Jozef, De Bruyne Bernard, Barbato Emanuele. DISENGAGE Registry.. Circulation. Cardiovascular interventions. 2020. DOI: 10.1161/circinterventions.119.008640.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.