The American journal of cardiology · 2020
Bioresorbable Vascular Scaffolds Versus Drug-Eluting Stents for Diffuse Long Coronary Narrowings.
Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Seo Jongkwon, Ahn Jung-Min, Hong Sung-Jin, Kang Do-Yoon, Hong Soon Jun, Her Ae-Young, Kim Yong Hoon, Ahn Chul-Min, Kim Jung-Sun, Kim Byeong-Keuk, Ko Young-Guk, Choi Donghoon, Jang Yangsoo, Park Seung-Jung, Park Duk-Woo, Hong Myeong-Ki
Аннотация
Clinical benefits of bioresorbable vascular scaffold (BVS) implantation for long coronary lesions were not sufficiently evaluated. The efficacy and safety of BVS and metallic everolimus-eluting stent (EES) were compared for the treatment of long coronary narrowings. A total of 341 patients with diffuse long lesions (requiring device length ≥28 mm) were randomized to receive either BVS (n = 171) or EES (n = 170) implantation. The primary endpoint was major adverse cardiovascular events which included death from cardiac cause, myocardial infarction, device thrombosis, or ischemia-driven target-lesion revascularization at 12 months. The trial was terminated early because the manufacturer stopped supplying BVS. The mean lesion length was 32.2 ± 13.1 mm in the BVS group and 35.3 ± 13.0 mm in the EES group. The 12-month follow-up was completed in 332 patients (97.4%). At 12 months, the primary endpoint events occurred in 2 patients (1.2%) in the BVS group and in 4 patients (2.4%) in the EES group (hazard ratio = 0.49, 95% confidence interval = 0.09 to 2.67, p = 0.398). Definite or probable device thrombosis occurred in 1 patient (0.6%) in the BVS group and 1 patient (0.6%) in the EES group (hazard ratio = 1.00, 95% confidence interval = 0.06 to 15.94, p = 0.998). In conclusion, in patients with long native coronary artery disease, significant differences between BVS and EES were not observed regarding the primary composite endpoint of death from cardiac cause, myocardial infarction, device thrombosis, or target-lesion revascularization at 12 months. However, due to the early termination of this trial and a low number of events, the results cannot be considered clinically relevant (clinicalTrials.gov Identifier: NCT02796157).
Предметные рубрики MeSH
Absorbable ImplantsAgedAngina, StableAngina, UnstableCoronary Artery DiseaseDrug-Eluting StentsEarly Termination of Clinical TrialsEverolimusFemaleHeart DiseasesHumansImmunosuppressive AgentsMaleMiddle AgedMyocardial InfarctionMyocardial RevascularizationPercutaneous Coronary InterventionProportional Hazards ModelsProsthesis DesignThrombosisTissue Scaffolds