Artificial Intelligence-Accelerated vs. Conventional Diffusion-Weighted Imaging for Prostate MRI: Comparing Quality and Quantitative Metrics.

Sacalean Vlad, Gebler Oliver, Liu Wei, Strecker Ralph, Weiland Elisabeth, Bamberg Fabian, Weiß Jakob, Russe Maximilian F, Engel Hannes

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

Diffusion-weighted imaging (DWI) is central to prostate magnetic resonance imaging (MRI) but lengthens examinations. We evaluated whether an artificial intelligence (AI)-accelerated, reduced-field-of-view diffusion sequence (AI-DWI) could shorten scan time without sacrificing perceived diagnostic image quality, and how it affects quantitative diffusion metrics.

MATERIALS AND

METHODS

This prospective, single-center study of diagnostic accuracy enrolled consecutive men with elevated prostate-specific-antigen levels between March and May 2025. The index AI-DWI sequence was compared against the standard conventional DWI sequence (c-DWI) for each patient. Three radiologists scored subjective image quality. Quantitative analysis involved comparing mean apparent diffusion coefficient (ADC) and seven additional texture features. Wilcoxon signed-rank tests assessed ordinal scores, and paired t-tests were used for quantitative metrics.

RESULTS

62 men (mean age, 68.7 years ± 9) were evaluated. The AI-DWI sequence demonstrated a significantly shorter acquisition time compared to c-DWI (3 min 59 s vs. 4 min 21 s; p<0.01). There was no significant difference in subjective scores for overall image quality, lesion conspicuity, artifacts, or anatomic differentiability (p>0.05 for all). AI-DWI yielded significantly lower mean ADC values (975.92±174.57 vs. 1013.21±189.34; adj. p<0.01) and maximum ADC values (adj. p<0.01). No significant differences were found for standard deviation, coefficient of variation, entropy, kurtosis, minimum, or skewness (adj. p>0.05).

CONCLUSION

The AI-DWI sequence allows for reduced acquisition time while preserving subjective image quality compared to the c-DWI. Quantitatively, it yields lower mean and maximum ADC values, while showing no significant differences in the rest of the quantitative metrics relative to the conventional sequence.

Для цитирования: Sacalean Vlad, Gebler Oliver, Liu Wei, Strecker Ralph, Weiland Elisabeth, Bamberg Fabian, Weiß Jakob, Russe Maximilian F, Engel Hannes. Artificial Intelligence-Accelerated vs. Conventional Diffusion-Weighted Imaging for Prostate MRI: Comparing Quality and Quantitative Metrics.. Academic radiology. 2025. DOI: 10.1016/j.acra.2025.12.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.