MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081-597x-20041101-11

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2004

Wavefront aberrations associated with the Ferrara intrastromal corneal ring in a keratoconic eye.

Chalita Maria Regina, Krueger Ronald R

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the optical implications of the aberration pattern of a keratoconic eye implanted with an intrastromal corneal ring (Ferrara ring).

METHODS

A 32-year-old man with bilateral keratoconus had a Ferrara intrastromal corneal ring implanted in his right eye. Surgery was uneventful and both uncorrected (UCVA) and best spectacle-corrected (BSCVA) visual acuity improved. Corneal topography was performed before and after surgery. Wavefront measurements were performed 1 month after the procedure in both eyes for comparison. The point spread function, modulation transfer function (MTF), and convolved acuity chart were analyzed.

RESULTS

The right eye--implanted with the intrastromal Ferrara ring--had high root-mean-square (RMS) values for higher order aberrations. The left eye-keratoconus without an intrastromal ring-had moderate values. Point spread function, MTF, and convolution acuity charts are presented for each eye, with the latter two showing improved visual function in the implanted eye, despite a higher aberration value.

CONCLUSION

The wavefront measurement device captured aberrations even in a highly aberrated eye. Despite better UCVA and BSCVA, the Ferrara ring notably increased higher order aberrations compared to the fellow eye, but with a more uniform central pattern. In this case, the larger RMS value was a poor predictor of good visual function; other metrics better predicted the patient's subjective response. Metrics other than RMS error may be necessary to better correlate aberration value with visual satisfaction in some eyes.

Для цитирования: Chalita Maria Regina, Krueger Ronald R. Wavefront aberrations associated with the Ferrara intrastromal corneal ring in a keratoconic eye.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2004. DOI: 10.3928/1081-597x-20041101-11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.