MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9394(02)01698-7

Медицинская библиотека · American journal of ophthalmology · 2002

Keratocyte density in keratoconus. A confocal microscopy study(a).

Erie Jay C, Patel Sanjay V, McLaren Jay W, Nau Cherie B, Hodge David O, Bourne William M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To estimate keratocyte density in human corneas with keratoconus by confocal microscopy.

DESIGN

Prospective, observational cohort study.

METHODS

Twenty-nine unscarred corneas of 19 patients with keratoconus and 29 corneas of 19 controls matched for age (+/-3 years) and contact lens wear were examined by using confocal microscopy. Images were recorded from the full-thickness central cornea. A masked observer manually counted bright objects (keratocyte nuclei) in images without motion blur. Cell densities in anteroposterior stromal layers of keratoconus corneas were compared with densities in corresponding layers of control corneas.

RESULTS

In keratoconus patients, age 40 +/- 15 years (mean +/- standard deviation), keratocyte density was 19% lower in those who wore contact lenses (16,894 +/- 4032 cell/mm(3), n = 12) than in those who did not wear contact lenses (20,827 +/- 4934 cell/mm(3), n = 17, P =.03). In control patients, age 39 +/- 16 years, there was no difference in keratocyte density between those who wore contact lenses (n = 12) and those who did not wear contact lenses (n = 17, P =.80). Among contact lens wearers, keratocyte density was 25% lower in keratoconus corneas (16,894 +/- 4, 032 cell/mm(3), n = 12 [9 = rigid gas-permeable lenses, 3 = soft lenses]) than in control corneas (22,579 +/- 2, 387 cell/mm(3), n = 12 [3 = rigid gas-permeable lenses, 9 = soft lenses], P =.002), the result of cell density being lower in the most anterior keratocyte layer (P =.001) and the layers between 0% to 10% (P <.001), 67% to 90% (P <.001), and 91% to 100% (P <.001) of stromal thickness. Among noncontact lens wearers, there was no difference in cell density between keratoconus and controls (P =.41).

CONCLUSION

Keratocyte density is decreased in the anterior and posterior stroma of keratoconus patients who wear contact lenses.

Для цитирования: Erie Jay C, Patel Sanjay V, McLaren Jay W, Nau Cherie B, Hodge David O, Bourne William M. Keratocyte density in keratoconus. A confocal microscopy study(a).. American journal of ophthalmology. 2002. DOI: 10.1016/s0002-9394(02)01698-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.