MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0161-6420(02)01121-1

Медицинская библиотека · Ophthalmology · 2002

Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery.

Rao Sanjay N, Raviv Tal, Majmudar Parag A, Epstein Randy J

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the relationship between videokeratographic keratoconus screening programs and Orbscan II topography.

DESIGN

Prospective, observational case series and instrument validation study.

PARTICIPANTS

Sixty consecutive eyes with suspicious videokeratography (TMS-1, Tomey Technology, Waltham, MA) were evaluated before undergoing laser in situ keratomileusis (LASIK) surgery. A control group of 50 consecutive eyes without suspicious features by videokeratography was also evaluated.

METHODS

Keratoconus screening programs, using the Rabinowitz and Klyce/Maeda methods and Orbscan II (Bausch & Lomb, Claremont, CA) topographies were performed on these patients.

MAIN OUTCOME MEASURES: Specific parameters evaluated on the Orbscan II topographies were anterior elevation, posterior elevation, and thinnest pachymetry.

RESULTS

Compared with a control group of patients without suspicious videokeratography, there was a statistically significant difference in the mean posterior elevation and mean anterior elevation in the groups with positive keratoconus testing with the Rabinowitz or Klyce/Maeda methods. For patients who met both the Rabinowitz and Klyce/Maeda criteria for keratoconus, the mean posterior elevation was 44 +/- 2.5 micro m compared with a posterior elevation of 21 +/- 0.6 micro m for the control group. There was no statistically significant difference in the mean thinnest pachymetry between the control group and all keratoconus suspect groups.

CONCLUSIONS

Patients with positive keratoconus screening tests have higher anterior and posterior elevation on Orbscan II topography. When used in combination with videokeratography, the Orbscan II topography system may be helpful in identifying patients who are potentially at high risk for developing ectasia after LASIK.

Для цитирования: Rao Sanjay N, Raviv Tal, Majmudar Parag A, Epstein Randy J. Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery.. Ophthalmology. 2002. DOI: 10.1016/s0161-6420(02)01121-1.