MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00006324-200208000-00011

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2002

Visual performance and comfort with the Rose K lens for keratoconus.

Betts Aaron M, Mitchell G Lynn, Zadnik Karla

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The "Rose K Lens for Keratoconus" is a proprietary rigid contact lens design that has been reported and marketed as a lens that provides better visual acuity and comfort than other rigid contact lens designs for keratoconus.

METHODS

Twenty patients with keratoconus who were wearing rigid contact lenses were refitted into the Rose K lenses. Visual acuity measurements were taken with habitual lenses at the baseline visit and with the Rose K lenses at the completion of the study. Questionnaires were used to assess vision-specific quality of life, contact lens comfort, and self-reported assessment of vision.

RESULTS

There were no statistically significant changes in high- or low-contrast visual acuity with the Rose K lenses. There was statistically significant improvement in self-reported assessment of vision and self-reported assessment of comfort in the eyes with more advanced keratoconus. At the conclusion of the study, 72% of patients preferred the Rose K lenses over their habitual lenses, and 87% reported that they would continue wearing the Rose K lenses.

CONCLUSIONS

There was no difference in the visual acuity with the Rose K lenses compared with the patients' habitual lenses. Subjective assessment of vision and comfort indicate a statistical improvement for more advanced keratoconus with the Rose K lens. We could not rule out a placebo effect as a source of subjective improvement in vision and comfort. Nevertheless, the successful fit rate and patient preference demonstrate the usefulness of the Rose K lens in clinical practice.

Для цитирования: Betts Aaron M, Mitchell G Lynn, Zadnik Karla. Visual performance and comfort with the Rose K lens for keratoconus.. Optometry and vision science : official publication of the American Academy of Optometry. 2002. DOI: 10.1097/00006324-200208000-00011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.