MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40729-025-00648-0

Медицинская библиотека · International journal of implant dentistry · 2025

Accuracy of dynamic computer-assisted implant surgery across different degrees of edentulism: does experience matter? An in vitro study.

Böse Mats Wernfried Heinrich, Jung Alexander, Beuer Florian, Pieralli Stefano, Nensa Moritz, Bruhnke Maria

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of a dynamic computer-assisted implant surgery (dCAIS) system utilized by two clinicians with differing levels of surgical experience in implant dentistry.

METHODS

A total of 72 conical dental implants were placed into 18 jaw models using a dCAIS system (Navident, ClaroNav, Toronto, Canada). Implant planning and placement were performed by both a novice and an experienced implantologist, following a standardized protocol across single-tooth gaps, shortened dental arches, and fully edentulous jaws. Pre- and postoperative CBCT scans were aligned, and deviations were analyzed at the coronal entry point (2D), apex (3D), apex vertically (V) and in angular deviation (°). Level of significance was set at p < 0.05.

RESULTS

Mean deviations across all implants placed were: 1.25 ± 0.90 mm at entry point (2D), 1.66 ± 0.68 mm at apex (3D), 0.70 ± 0.51 mm at apex (V) and 4.96 ± 3.16° angular. No statistically significant differences were found between clinicians, jaws, or sides (p > 0.05). However, a significant correlation was observed regarding accuracy at entry points and angular deviations, indicating lower accuracy in fully edentulous jaws (p < 0.05).

CONCLUSIONS

The investigated dCAIS system enabled accurate transfer of the planned to the actual (in vitro) implant position independent of operator experience. dCAIS systems may help mitigate the impact of limited surgical experience and contribute to more predictable outcomes. However, reduced anatomical reference points in edentulous jaws justify further clinical investigation and workflow optimization.

Для цитирования: Böse Mats Wernfried Heinrich, Jung Alexander, Beuer Florian, Pieralli Stefano, Nensa Moritz, Bruhnke Maria. Accuracy of dynamic computer-assisted implant surgery across different degrees of edentulism: does experience matter? An in vitro study.. International journal of implant dentistry. 2025. DOI: 10.1186/s40729-025-00648-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.