A comparison of two methods of evaluating cornea-to-contact lens base curve fluorescein patterns in keratoconus.

Fink B A, Barr J T, Edrington T B, Pierce G E, Schechtman K B, Rah M J, Flom R, Zadnik K, CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The purposes of the study were as follows: (1) to compare the apical fitting relationship of habitual contact lens fluorescein patterns in keratoconus as determined by clinician assessment of on-eye patterns to those determined by photograph readers looking at slides of fluorescein patterns and (2) to determine the validity of the techniques used in assessing the apical fitting relationships of rigid corneal contact lenses on keratoconic corneas.

METHODS

Central fluorescein patterns of rigid contact lens-wearing keratoconus patients enrolled in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study were graded as "definite touch," "touch," "clearance," or "definite clearance" by certified clinicians. Photographs of these patterns were evaluated independently by certified, masked photograph readers using the same grading scale.

RESULTS

Agreement between "re-reads" of the same fluorescein pattern slides by the photograph readers was substantial (weighted kappa = 0.751). Agreement between assessments of habitual fit fluorescein patterns at the baseline vs. the repeat visits was poor for the photograph readers (weighted kappa = 0.254) and moderate for the clinicians (kappa = 0.480). Agreement between clinicians' and photograph readers' assessment of the habitual contact lens fluorescein pattern at the baseline visit was fair (weighted kappa = 0.382).

CONCLUSIONS

Repeatability and validity of this technique were fair to excellent. Many factors influence fluorescein pattern interpretation, and improvement of the objective method of fluorescein pattern assessment by photograph readers will require improved methodology that takes these factors into consideration.

Для цитирования: Fink B A, Barr J T, Edrington T B, Pierce G E, Schechtman K B, Rah M J, Flom R, Zadnik K, CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus. A comparison of two methods of evaluating cornea-to-contact lens base curve fluorescein patterns in keratoconus.. Optometry and vision science : official publication of the American Academy of Optometry. 2001. DOI: 10.1097/00006324-200108000-00011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.