MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrtlng.2023.05.017

Медицинская библиотека · Heart & lung : the journal of critical care · 2023

Evaluation of the relationship of tricuspid regurgitation peak gradient/tricuspid annulus plane systolic excursion to exercise capacity, cardiac index, and ventilatory function during exercise in patients with COPD.

Lan Chou-Chin, Yeh Kuan-Hung, Tzeng I-Shiang, Hsieh Po-Chun, Yang Mei-Chen, Wu Chih-Wei, Su Wen-Lin, Wu Yao-Kuang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Chronic obstructive pulmonary disease (COPD) often causes cardiopulmonary dysfunction, which deteriorates exercise capacity. Cardiopulmonary exercise testing (CPET) and echocardiography are common tools for evaluating cardiovascular function. No studies have analyzed the correlation between echocardiography-derived parameters and cardiopulmonary response during exercise.

OBJECTIVES

We analyzed the correlation between echocardiographic parameters such as tricuspid regurgitation peak gradient (TRPG), tricuspid annular plane systolic excursion (TAPSE), TRPG/TAPSE and CPET-derived parameters.

METHODS

Seventy-seven patients with COPD were evaluated. We analyzed the correlation between parameters derived from echocardiography, exercise capacity, cardiovascular and ventilatory parameters derived from CPET.

RESULTS

The correlation between TRPG/TAPSE and work rate (WR) was moderate and negative (-0.4423, p = 0.0003), while TRPG had a weak negative correlation with WR (r= -0.3099, p = 0.0127). Oxygen uptake at peak exercise was weakly negatively correlated with TRPG/TAPSE (-0.3404, p = 0.0059), TRPG (r= -0.3123, p = 0.0120), and the ratio of early mitral inflow velocity to early mitral annular diastolic velocity (E/E'). The correlation between TRPG/TAPSE and exercise capacity was higher than that of TPRG, TAPSE, and E/E'. TRPG/TAPSE exhibited a moderate negative correlation with cardiac index, whereas TRPG and TAPSE showed a weak correlation. The correlation between TRPG/TAPSE and cardiac function during exercise was higher than that of TPRG, TAPSE, and E/E'. TRPG/TAPSE, TRPG, TAPSE, and E/E' were weakly negatively correlated with lung function.

CONCLUSIONS

In assessing exercise capacity, cardiac function, and gas exchange, TRPG/TAPSE proves to be superior to other cardiac parameters. Higher TRPG/TAPSE levels corresponded to lower exercise capacity, cardiovascular and ventilatory function.

Для цитирования: Lan Chou-Chin, Yeh Kuan-Hung, Tzeng I-Shiang, Hsieh Po-Chun, Yang Mei-Chen, Wu Chih-Wei, Su Wen-Lin, Wu Yao-Kuang. Evaluation of the relationship of tricuspid regurgitation peak gradient/tricuspid annulus plane systolic excursion to exercise capacity, cardiac index, and ventilatory function during exercise in patients with COPD.. Heart & lung : the journal of critical care. 2023. DOI: 10.1016/j.hrtlng.2023.05.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.