DOI 10.1016/j.hrtlng.2023.05.017
Evaluation of the relationship of tricuspid regurgitation peak gradient/tricuspid annulus plane systolic excursion to exercise capacity, cardiac index, and ventilatory function during exercise in patients with COPD.
Аннотация
BACKGROUND
Chronic obstructive pulmonary disease (COPD) often causes cardiopulmonary dysfunction, which deteriorates exercise capacity. Cardiopulmonary exercise testing (CPET) and echocardiography are common tools for evaluating cardiovascular function. No studies have analyzed the correlation between echocardiography-derived parameters and cardiopulmonary response during exercise.
OBJECTIVES
We analyzed the correlation between echocardiographic parameters such as tricuspid regurgitation peak gradient (TRPG), tricuspid annular plane systolic excursion (TAPSE), TRPG/TAPSE and CPET-derived parameters.
METHODS
Seventy-seven patients with COPD were evaluated. We analyzed the correlation between parameters derived from echocardiography, exercise capacity, cardiovascular and ventilatory parameters derived from CPET.
RESULTS
The correlation between TRPG/TAPSE and work rate (WR) was moderate and negative (-0.4423, p = 0.0003), while TRPG had a weak negative correlation with WR (r= -0.3099, p = 0.0127). Oxygen uptake at peak exercise was weakly negatively correlated with TRPG/TAPSE (-0.3404, p = 0.0059), TRPG (r= -0.3123, p = 0.0120), and the ratio of early mitral inflow velocity to early mitral annular diastolic velocity (E/E'). The correlation between TRPG/TAPSE and exercise capacity was higher than that of TPRG, TAPSE, and E/E'. TRPG/TAPSE exhibited a moderate negative correlation with cardiac index, whereas TRPG and TAPSE showed a weak correlation. The correlation between TRPG/TAPSE and cardiac function during exercise was higher than that of TPRG, TAPSE, and E/E'. TRPG/TAPSE, TRPG, TAPSE, and E/E' were weakly negatively correlated with lung function.
CONCLUSIONS
In assessing exercise capacity, cardiac function, and gas exchange, TRPG/TAPSE proves to be superior to other cardiac parameters. Higher TRPG/TAPSE levels corresponded to lower exercise capacity, cardiovascular and ventilatory function.