m+Medelevator.RU
← Поиск публикаций
Clinical oral investigations · 2023

Effect of the implant apical exposure and coverage < or ≥ 2 mm bone graft on transcrestal sinus floor elevation: a 1- to 7-year retrospective cohort study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gao Jiayu, Zhao Xiangqi, Man Yi, Qu Yili

Аннотация

OBJECTIVES: This study aimed to analyze the effect of the apex coverage by the bone graft, including exposure and coverage less than or greater than 2 mm on implant survival rate and peri-implant bone and soft tissue remodeling.

MATERIALS AND METHODS: A total of 264 implants in 180 patients who had undergone transcrestal sinus floor elevation (TSFE) with simultaneous implant placement were included in this retrospective cohort study. Radiographic assessment was used to categorize the implants into three groups based on apical implant bone height (ABH): ≤ 0 mm, < 2 mm, or ≥ 2 mm. The implant survival rate, peri-implant marginal bone loss (MBL) during short-term (1-3 years) and mid- to long-term (4-7 years) follow-up, and clinical parameters were used to evaluate the effect of implant apex coverage after TSFE.

RESULTS: Group 1 had 56 implants (ABH ≤ 0 mm), group 2 had 123 implants (ABH > 0 mm, but < 2 mm), and group 3 had 85 implants (ABH ≥ 2 mm). There was no significant difference in the implant survival rate between groups 2 and 3 compared to group 1 (p = 0.646, p = 0.824, respectively). The MBL during short-term and mid- to long-term follow-up indicated that apex coverage could not be considered a risk factor. Furthermore, apex coverage did not have a significant effect on other clinical parameters.

CONCLUSIONS: Despite limitations, our study found that implant apex coverage by the bone graft, including exposure and coverage levels less than or greater than 2 mm, did not significantly affect implant survival, short-term or mid- to long-term MBL, or peri-implant soft tissue outcomes.

CLINICAL RELEVANCE: Based on 1- to 7-year data, the study suggests that implant apical exposure and coverage levels of less than or greater than 2 mm bone graft are both valid options for TSFE cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты