MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.str.0000081000.23561.61

Медицинская библиотека · Stroke · 2003

Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients.

Cremonesi Alberto, Manetti Raffaella, Setacci Francesco, Setacci Carlo, Castriota Fausto

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Periprocedural embolization of debris during carotid stenting interventions may result in neurological deficit. This study was designed to evaluate in-hospital and 30-day adverse events in patients percutaneously treated for carotid artery disease with embolic protection devices.

METHODS

From 1999 to June 2002, a total of 442 consecutive patients underwent percutaneous angioplasty and/or stenting of the extracranial carotid artery. The endovascular procedure was conducted under embolic protection devices.

RESULTS

The percutaneous procedure was successful in 440 of 442 patients (99.5%). No periprocedural death occurred with any embolic protection device. All in-hospital stroke/death and 30-day ipsilateral stroke/death rate was 1.1%. The overall complication rate was 3.4%. Major adverse events included 1 major stroke (0.2%), 4 intracranial hemorrhages (0.9%), 1 carotid artery wall fissuration (0.2%), and 1 diffuse cardioembolism (0.2%). Minor adverse events included 4 minor strokes (0.9%) and 4 transient ischemic attacks (0.9%). The cerebral protection device-related complications were 4 (0.9%): 1 case of abrupt closure of the internal carotid artery because of spiral dissection (0.2%), 1 case of trapped guide wire (0.2%), and 2 cases of intimal dissection (0.5%). Transient loss of consciousness, tremors, and fasciculations were present in 6 of 40 patients (15%) in whom occlusive protection devices were used.

CONCLUSIONS

Our data suggest that percutaneous stenting of the carotid artery when a cerebral protection device is used is feasible and effective but not without potential complications. However, a long learning curve may exist for the proper use of some embolic protection devices.

Для цитирования: Cremonesi Alberto, Manetti Raffaella, Setacci Francesco, Setacci Carlo, Castriota Fausto. Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients.. Stroke. 2003. DOI: 10.1161/01.str.0000081000.23561.61.