DOI 10.1016/j.jtos.2019.06.003
Ocular surface assessment and morphological alterations in meibomian glands with meibography in obstructive sleep apnea Syndrome.
Аннотация
PURPOSE: To evaluate ocular surface and Meibomian glands morphology of patients with obstructive sleep apnea syndrome (OSAS).
MATERIALS AND
METHODS
Based on polysomnography, 36 eyes of 36 patients with severe OSAS (Group 1, apnea-hypopnea index (AHI) ≥30/h) and 24 eyes of 24 patients with primary snoring or mild OSAS (Group 2, AHI<15/h) were enrolled. Detailed eye examination along with ocular surface staining (fluorescein, 2%) according to Oxford scale, tear film break-up time (t-BUT), Schirmer 1 test, ocular surface disease index (OSDI) scoring, and evaluation of upper and lower eyelid Meibomian glands using infrared filter of slit-lamp biomicroscope were performed. In addition to grading Meibomian gland drop-out, the presence morphologic alterations such as Meibomian gland duct distortion, thinning and dilatation were also assessed.
RESULTS
The mean ages were 50.8 ± 8.3 (range, 35-68) and 47.9 ± 10.5 (range, 27-69) in Group 1 and Group 2, respectively (p = 0.616). Best-corrected visual acuity, Schirmer 1 test, Oxford scale and OSDI scores, and lower meiboscores did not differ significantly between groups. In Group 1, average t-BUT was lower (p = 0.003), upper and total (upper + lower) meiboscores were higher as compared to Group 2 (p < 0.05). The frequency of Meibomian gland duct distortion, thinning and dilatation were also significantly greater in Group 1 (p < 0.05).
CONCLUSION
Morphological changes, in addition to Meibomian glands dropout were significant in severe OSAS patients as demonstrated objectively with meibography. Schirmer 1 and t-BUT tests were in favor of evaporative type dry eye syndrome, which also support Meibomian gland alterations in severe OSAS patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.