Dry eye is matched by increased intrasubject variability in tear osmolarity as confirmed by machine learning approach.

Cartes C, López D, Salinas D, Segovia C, Ahumada C, Pérez N, Valenzuela F, Lanza N, López Solís R O, Perez V L, Zegers P, Fuentes A, Alarcón C, Traipe L

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Because of high variability, tear film osmolarity measures have been questioned in dry eye assessment. Understanding the origin of such variability would aid data interpretation. This study aims to evaluate osmolarity variability in a clinical setting.

MATERIAL AND

METHODS

Twenty dry eyes and 20 control patients were evaluated. Three consecutive osmolarity measurements per eye at 5min intervals were obtained. Variability was represented by the difference between both extreme readings per eye. Machine learning techniques were used to quantify discrimination capacity of tear osmolarity for dry eye.

RESULTS

Mean osmolarities in the control and dry eye groups were 295.1±7.3mOsm/L and 300.6±11.2mOsm/L, respectively (P=.004). Osmolarity variabilities were 7.5±3.6mOsm/L and 16.7±11.9mOsm/L, for the control and dry eye groups, respectively (P<.001). Based on osmolarity, a logistic classifier showed an 85% classification accuracy.

CONCLUSIONS

In the clinical setting, both mean osmolarity and osmolarity variability in the dry eye group were significantly higher than in the control group. Machine learning techniques showed good classification accuracy. It is concluded that higher variability of tear osmolarity is a dry eye feature.

Для цитирования: Cartes C, López D, Salinas D, Segovia C, Ahumada C, Pérez N, Valenzuela F, Lanza N, López Solís R O, Perez V L, Zegers P, Fuentes A, Alarcón C, Traipe L. Dry eye is matched by increased intrasubject variability in tear osmolarity as confirmed by machine learning approach.. Archivos de la Sociedad Espanola de Oftalmologia. 2019. DOI: 10.1016/j.oftal.2019.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.