MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001954

Медицинская библиотека · Cornea · 2019

Expressible Meibomian Glands Have Occult Fixed Obstructions: Findings From Meibomian Gland Probing to Restore Intraductal Integrity.

Maskin Steven L, Alluri Sreevardhan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe and quantify findings of intraductal obstruction during probing expressible and nonexpressible meibomian glands (MGs) in patients with obstructive meibomian gland dysfunction using a 1-mm intraductal MG probe.

METHODS

A retrospective study of probe findings from 108 consecutive patients. Nonparametric tests using SPSS software 25.0 to explore relationships between expressibility and probe findings.

RESULTS

Of 11,776 probed glands of 404 lids, 84% showed mechanical resistance (MR) and 16% showed no resistance (NR). Fixed, firm, focal unyielding resistance (FFFUR) occurred in 79.5% of obstructed glands, and nonfixed, nonfocal easily yielding soft resistance (SFT) in 20.4%. FFFUR was characterized by an audible and tactile "firm pop" (FP) or "firm gritty" (FG) sensation. No significant difference in MR and FFFUR for lids between 0% and >90% gland expressibility was observed. FP correlated with increased expressibility (P = 0.011), lid tenderness (P = 0.045), and complete proximal obstruction (P = 0.037), whereas SFT correlated with reduced expressibility (P = 0.016). Upper lids showed greater incidence of MR (P < 0.001), FFFUR (P < 0.001), and FG (P < 0.001), whereas lower lids showed greater expressibility (P < 0.001) and NR (P < 0.001).

CONCLUSIONS

FFFUR was the most common probe finding in a large series of consecutively probed MGs, with an incidence of 67% of glands and 80% of obstructed glands. FFFUR was independent of gland expressibility, demonstrating expressible glands harbor FFFUR deep to at least one acinus. FP was associated with expressible gland occult obstruction and lid tenderness. SFT correlated with reduced expressibility, perhaps related to altered duct/duct contents. Upper lids correlated with increased MR, FFFUR, and FG and lower lids with increased expressibility and NR, possibly reflecting contrasting anatomy and blink-related microtrauma.

Для цитирования: Maskin Steven L, Alluri Sreevardhan. Expressible Meibomian Glands Have Occult Fixed Obstructions: Findings From Meibomian Gland Probing to Restore Intraductal Integrity.. Cornea. 2019. DOI: 10.1097/ico.0000000000001954.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.