MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2019.04.004

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2019

The influence of meibomian gland loss on ocular surface clinical parameters.

Rico-Del-Viejo Laura, Benítez-Del-Castillo José Manuel, Gómez-Sanz Fernando Javier, García-Montero María, Llorens-Quintana Clara, Madrid-Costa David

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the relationship between the meibomian gland loss (MGL) and relevant ocular surface clinical parameters as well as the influence of age in this relationship.

METHODS

A total of 161 participants (mean age; 42±17 years) were enrolled in this study. Infrared meibography was performed using Keratograph 5M (K5M; Oculus GmbH, Wetzlar). Participants were divided into five groups according to total meiboscore and the ocular surface parameters of each MGL group were studied. In addition, the relationship between MGL and the ocular surface parameters was established including age as covariant.

RESULTS

Both eyelids were taken into account since no association between the MGL from upper and lower eyelid was found (k value=0.2; p=0.3) despite they were significantly correlated (r= 0.3; p<0.001). No statistically significant differences were found in symptomatology among different MGL groups. Statistically significant differences were found among MGL groups in tear osmolarity (p=0.02), bulbar redness (p=0.04), corneal and conjunctival staining (p=0.01 and p=0.004, respectively). Despite this, only corneal staining showed a significant correlation with MGL when age was covariant (r=0.2; p=0.04).

CONCLUSIONS

MGL higher than 50% seems to be accompanied by signs on the ocular surface. Furthermore, age demonstrated to be a relevant factor when assessing MGL. For this reason, future studies should compare age-matched groups in order to know the contribution of the MGL on the ocular surface and establish valid cut-off values for dry eye diagnosis.

Для цитирования: Rico-Del-Viejo Laura, Benítez-Del-Castillo José Manuel, Gómez-Sanz Fernando Javier, García-Montero María, Llorens-Quintana Clara, Madrid-Costa David. The influence of meibomian gland loss on ocular surface clinical parameters.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2019. DOI: 10.1016/j.clae.2019.04.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.