MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3346/jkms.2015.30.3.245

Медицинская библиотека · Journal of Korean medical science · 2015

The potential utility of iodinated contrast media (ICM) skin testing in patients with ICM hypersensitivity.

Ahn Young-Hwan, Koh Young-Il, Kim Joo-Hee, Ban Ga-Young, Lee Yeon-Kyung, Hong Ga-Na, Jin U-Ram, Choi Byung-Joo, Shin Yoo-Seob, Park Hae-Sim, Ye Young-Min

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Both immediate and delayed hypersensitivity reactions to iodinated contrast media (ICM) are relatively common. However, there are few data to determine the clinical utility of immunologic evaluation of ICM. To evaluate the utility of ICM skin testing in patients with ICM hypersensitivity, 23 patients (17 immediate and 6 delayed reactions) were enrolled from 3 university hospitals in Korea. With 6 commonly used ICM including iopromide, iohexol, ioversol, iomeprol, iopamidol and iodixanol, skin prick (SPT), intradermal (IDT) and patch tests were performed. Of 10 patients with anaphylaxis, 3 (30.0%) and 6 (60.0%) were positive respectively on SPTs and IDTs with the culprit ICM. Three of 6 patients with urticaria showed positive IDTs. In total, 11 (64.7%) had positive on either SPT or IDT. Three of 6 patients with delayed rashes had positive response to patch test and/or delayed IDT. Among 5 patients (3 anaphylaxis, 1 urticaria and 1 delayed rash) taken subsequent radiological examinations, 3 patients administered safe alternatives according to the results of skin testing had no adverse reaction. However, anaphylaxis developed in the other 2 patients administered the culprit ICM again. With 64.7% (11/17) and 50% (3/6) of the sensitivities of corresponding allergic skin tests with culprit ICM for immediate and delayed hypersensitivity reactions, the present study suggests that skin tests is useful for the diagnosis of ICM hypersensitivity and for selecting safe ICM and preventing a recurrence of anaphylaxis caused by the same ICM.

Для цитирования: Ahn Young-Hwan, Koh Young-Il, Kim Joo-Hee, Ban Ga-Young, Lee Yeon-Kyung, Hong Ga-Na, Jin U-Ram, Choi Byung-Joo, Shin Yoo-Seob, Park Hae-Sim, Ye Young-Min. The potential utility of iodinated contrast media (ICM) skin testing in patients with ICM hypersensitivity.. Journal of Korean medical science. 2015. DOI: 10.3346/jkms.2015.30.3.245.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.