DOI 10.1159/000048501

Медицинская библиотека · Chemotherapy · 2001

Efficacy of a benzalkonium chloride-impregnated central venous catheter to prevent catheter-associated infection in cancer patients.

Jaeger K, Osthaus A, Heine J, Ruschulte H, Kuhlmann C, Weissbrodt H, Ganser A, Karthaus M

Клиническое исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

This study was performed to determine the efficacy of a benzalkonium chloride-impregnated central venous catheter (CVC) in preventing catheter-related infection in patients suffering from malignant diseases and undergoing chemotherapy.

METHODS

A randomized, prospective clinical trial was carried out to compare the incidence of catheter-related colonization and catheter-related bacteremia using an antiseptic-impregnated CVC (n = 25) with that using a standard triple-lumen CVC (n = 25).

RESULTS

All patients were treated with intensive chemotherapy for acute leukemia (n = 28), lymphoma (n = 17) or solid tumors (n = 5). Both study groups presented with similar data in regards to age, insertion site, duration of catheterization and neutropenia period during catheterization, demonstrating a comparable risk for catheter-related colonization. Suspicion of infection led to explantation in 14 versus 15 cases. Catheter-related colonization was proven in 4 cases (16%) and catheter-related bacteremia was observed only once (4%) in both groups. Statistical testing showed no significant differences between the study and control group.

CONCLUSIONS

The rate of catheter-related colonization was lower than suspected in this high-risk patient group. The use of benzalkonium chloride-impregnated CVC failed to decrease the incidence of catheter-related colonization and bacteremia in patients with a high risk of infectious complications.

Для цитирования: Jaeger K, Osthaus A, Heine J, Ruschulte H, Kuhlmann C, Weissbrodt H, Ganser A, Karthaus M. Efficacy of a benzalkonium chloride-impregnated central venous catheter to prevent catheter-associated infection in cancer patients.. Chemotherapy. 2001. DOI: 10.1159/000048501.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.