DOI 10.1148/radiology.209.2.9807569

Медицинская библиотека · Radiology · 1998

Comparison of inversion-recovery gradient- and spin-echo and fast spin-echo techniques in the detection and characterization of liver lesions.

Pijl M E, Wasser M N, van Persijn van Meerten E L, Gratama J W, van de Velde C J, Hermans J, Elevelt A, Bloem J L

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare respiratory-triggered inversion-recovery (IR) gradient- and spin-echo (GRASE) magnetic resonance (MR) imaging with respiratory-triggered T2-weighted fast spin-echo (SE) imaging in the diagnosis of liver metastases.

MATERIALS AND

METHODS

In this prospective study, two radiologists independently identified focal hepatic lesions on respiratory-triggered IR GRASE and respiratory-triggered fast SE MR images in 28 consecutive patients with 186 (135 malignant and 51 benign) proved lesions. A combination of findings at surgery, intraoperative ultrasonography (US), and histologic examination served as the standard of reference. Contrast-to-noise ratios (CNRs) were obtained from 86 lesions larger than 10 mm.

RESULTS

The sensitivity in the detection of liver metastases was, independent of lesion size and observer, higher for IR GRASE imaging (55%) than for fast SE imaging (44%-50%) (observer 1, P = .014; observer 2, P = .21). Confidence levels with IR GRASE imaging were higher, but not significantly so, than those with fast SE imaging (P < .098). Both observers characterized liver lesions better with IR GRASE than with fast SE imaging (observer 1, P = .04; observer 2, P = .48). The metastasis-liver CNR was significantly higher (P = .012) with IR GRASE imaging.

CONCLUSION

The respiratory-triggered IR GRASE sequence is a fast alternative to the respiratory-triggered fast SE sequence in the evaluation of suspected liver metastases.

Для цитирования: Pijl M E, Wasser M N, van Persijn van Meerten E L, Gratama J W, van de Velde C J, Hermans J, Elevelt A, Bloem J L. Comparison of inversion-recovery gradient- and spin-echo and fast spin-echo techniques in the detection and characterization of liver lesions.. Radiology. 1998. DOI: 10.1148/radiology.209.2.9807569.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.