Comparison of two different shapes of stylets for intubation with the McGrath MAC® video laryngoscope: a randomized controlled trial.
Аннотация
OBJECTIVE
This study was performed to compare two different shapes of stylets, 60° and J-shaped stylets, for intubation using the McGrath MAC® video laryngoscope (MVL).
METHODS
Two hundred twenty-two patients undergoing surgery under general anesthesia were randomly allocated to Group J (n = 111) or Group 60° (n = 111) and intubated using the MVL with the stylet bent into the allocated shape. The time to intubation (TTI) and other intubating profiles were compared between the groups. Multivariate regression analysis was used to determine the relationship between factors related to difficult intubation and TTI.
RESULTS
The TTI was not different between the two groups. There were also no differences in the intubating profiles between the two groups. In both groups, the TTI was longer with a modified Mallampati score (mMS) of ≥3 and percentage of glottic opening (POGO) score of <50. In Group J, the TTI was longer with a body mass index (BMI) of ≥30 kg/m2.
CONCLUSION
The TTI during tracheal intubation with the MVL was not different between the two groups. The TTI was longer with an mMS of ≥3 and POGO score of <50. In Group J, the TTI was longer with a BMI of ≥30 kg/m2.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.