MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.28637

Медицинская библиотека · The Laryngoscope · 2020

A Prospective Observational Study of Video Laryngoscopy Use in Difficult Airway Management.

Hyman Jaime B, Apatov David, Katz Daniel, Levine Adam I, DeMaria Samuel

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES/HYPOTHESIS: Video laryngoscopy has grown tremendously in popularity over the last decade for management of the anticipated difficult airway. The use of video laryngoscopy has not been adequately studied in the head and neck pathology patient population, including those with masses, previous head and neck surgery, or radiation.

STUDY

DESIGN

Prospective observational study.

METHODS

This study included 100 patients with head and neck pathology undergoing awake flexible bronchoscopic intubation for nonemergency surgery requiring general anesthesia. After the performance of awake flexible bronchoscopic intubation and induction of anesthesia, video laryngoscopy was performed with the CMAC D blade and Glidescope AVL. The primary outcome was the modified Cormack-Lehane view obtained on video laryngoscopy.

RESULTS

One hundred patients were enrolled in the study. After exclusions, 92 patients underwent video laryngoscopy with both the CMAC D blade and the Glidescope AVL. Thirty-seven patients (40.2%) had a Cormack-Lehane view ≥3 with the CMAC D blade, and 28 patients (30.4%) had a Cormack-Lehane view ≥3 with the Glidescope AVL. There were no complications from awake flexible bronchoscopic intubation or video laryngoscopy.

CONCLUSIONS

There is a high incidence of inability to obtain a view of the glottis with video laryngoscopy in patients with head and neck pathology, particularly airway masses.

LEVEL OF EVIDENCE: 3 Laryngoscope, 131:82-86, 2021.

Для цитирования: Hyman Jaime B, Apatov David, Katz Daniel, Levine Adam I, DeMaria Samuel. A Prospective Observational Study of Video Laryngoscopy Use in Difficult Airway Management.. The Laryngoscope. 2020. DOI: 10.1002/lary.28637.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.