American heart journal · 2024
Randomized comparison of TAVI valves: The Compare-TAVI trial.
Протокол клинического исследованияСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Terkelsen Christian Juhl, Thim Troels, Freeman Philip, Dahl Jordi Sanchez, Nørgaard Bjarne Linde, Kim Won-Yong, Tang Mariann, Sørensen Henrik Toft, Christiansen Evald Høj, Nissen Henrik
Аннотация
INTRODUCTION: Based on technical advancements and clinical evidence, transcatheter aortic valve implantation (TAVI) has been widely adopted. New generation TAVI valve platforms are continually being developed. Ideally, new valves should be superior or at least non-inferior regarding efficacy and safety, when compared to best-in-practice contemporary TAVI valves.
METHODS AND ANALYSIS: The Compare-TAVI trial (ClinicalTrials.gov NCT04443023) was launched in 2020, to perform a 1:1 randomized comparison of new vs contemporary TAVI valves, preferably in all comers. Consecutive cohorts will be launched with sample sizes depending on the choice of interim analyses, expected event rates, and chosen superiority or non-inferiority margins. Enrollment has just been finalized in cohort B, comparing the Sapien 3/Sapien 3 Ultra Transcatheter Heart Valve (THV) series (Edwards Lifesciences, Irvine, California, USA) and the Myval/Myval Octacor THV series (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) balloon expandable valves. This non-inferiority study was aimed to include 1062 patients. The 1-year composite safety and efficacy endpoint comprises death, stroke, moderate-severe aortic regurgitation, and moderate-severe valve deterioration. Patients will be followed until withdrawal of consent, death, or completion of 10-year follow-up, whichever comes first. Secondary endpoints will be monitored at 30 days, 1, 3, 5, and 10 years.
SUMMARY: The Compare-TAVI organization will launch consecutive cohorts wherein patients scheduled for TAVI are randomized to one of two valves. The aim is to ensure that the short- and long-term performance and safety of new valves being introduced is benchmarked against what achieved by best-in-practice contemporary valves.
METHODS AND ANALYSIS: The Compare-TAVI trial (ClinicalTrials.gov NCT04443023) was launched in 2020, to perform a 1:1 randomized comparison of new vs contemporary TAVI valves, preferably in all comers. Consecutive cohorts will be launched with sample sizes depending on the choice of interim analyses, expected event rates, and chosen superiority or non-inferiority margins. Enrollment has just been finalized in cohort B, comparing the Sapien 3/Sapien 3 Ultra Transcatheter Heart Valve (THV) series (Edwards Lifesciences, Irvine, California, USA) and the Myval/Myval Octacor THV series (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India) balloon expandable valves. This non-inferiority study was aimed to include 1062 patients. The 1-year composite safety and efficacy endpoint comprises death, stroke, moderate-severe aortic regurgitation, and moderate-severe valve deterioration. Patients will be followed until withdrawal of consent, death, or completion of 10-year follow-up, whichever comes first. Secondary endpoints will be monitored at 30 days, 1, 3, 5, and 10 years.
SUMMARY: The Compare-TAVI organization will launch consecutive cohorts wherein patients scheduled for TAVI are randomized to one of two valves. The aim is to ensure that the short- and long-term performance and safety of new valves being introduced is benchmarked against what achieved by best-in-practice contemporary valves.